96
Example:
GOC 3.000
Sets all the power supplies’ OCP value to 3.000 A.
GOCP
Description:
Configures/Queries the overcurrent protection state
of all the power supplies connected in the chain.
Example:
GOCP ON
Sets all the power supplies’ OCP state to ON.
GOP
Description:
Configures/Queries the overpower protection value
of all the power supplies connected in the chain.
Example:
GOP 300.00
Sets all the power supplies’ OPP value to 300.00
W.
GOPP
Description:
Configures/Queries the overpower protection state
of all the power supplies connected in the chain.
Example:
GOPP ON
Sets all the power supplies’ OPP state to ON.