Common Command Introduction
11
C1:BSWV WVTP, SINE,FRQ,100HZ,PERI,0.01S,AMP,2V, OFST,0V,HLEV,1V,LLEV,-1V,PHSE,0
Set noise bandwidth value of channel one to 100MHz
C1:BSWV BANDWIDTH, 100000000
2.14 Modulate Wave Command
Description
Sets or gets modulation parameters.
Command
<channel>:MoDulateWaVe<parameter>
Syntax
<channel>={C1, C2}
<parameter>={a parameter from the table below}
2.14.1 ParamtersTable
Parameters
Value
Description
STATE
<state>
Turn on or off modulation. Note: if you want
to set or read other parameters of modulation,
you must set STATE to ON at first.
AM, SRC
<src>
AM signal source.
AM, MDSP
<mod wave shape>
AM modulation wave. Only when AM sign al
source is set to INT, you can set the
parameter.
AM, FRQ
<AM frequency>
AM frequency. Only when AM signal sour ce
is set to INT, you can set the paramet er.
AM, DEPTH
<depth>
AM depth. Only when AM signal source is set
to INT, you can set the parameter.
DSBAM, SRC <src>
DSBAM signal source.
DSBAM, MDSP <mod wave shape>
DSBAM modulation wave. Only when AM
signal source is set to INT, you can set the
parameter.
DSBAM, FRQ <DSB-AM>< frequency> DSBAM frequency. Only when AM signal
source is set to INT, you can set the
parameter.
FM, SRC
<src>
FM signal source.
FM, MDSP
<mod wave shape>
FM modulation wave. Only when FM signal
source is set to INT, you can set the
parameter.
FM, FRQ
<FM frequency>
FM frequency. Only when FM signal source is
set to INT, you can set the parameter.
FM, DEVI
<FM frequency deviation > FM frequency deviation. Only when FM
signal source is set to INT. you can set the
parameter.
PM, SRC,
<src>
PM signal source.
Summary of Contents for 4060B Series
Page 1: ......