BK Precision 313C Manual Download Page 1

 

BK PRECISION 

313C 

P

INCE 

600A

 

TRMS

 

AC

 

/

 

DC 

600A

 

TRMS

 

AC

 

/

 

DC

 

CLAMP

 

METER 

 

   

       

 

 
 

 

 

 

 
 
 

 

    

 

M BK313C F00 

Summary of Contents for 313C

Page 1: ...BK PRECISION 313C PINCE 600A TRMS AC DC 600A TRMS AC DC CLAMP METER M BK313C F00...

Page 2: ...natifs 3 3 8 Courants alternatifs Mode Peak hold 3 3 9 R sistance 3 3 10 Continuit sonore 3 3 11 Temps de r ponse du Peak Hold 3 4 Description de l appareil 4 4 1 AFFICHEUR 4 4 2 PANNEAU AVANT ET ARRI...

Page 3: ...n Temp rature de fonctionnement 0 C 40 C HR 70 Temp rature de stockage 10 C to 60 C HR 80 Degr de pollution 2 Utilisation l int rieur altitude 2000m Symboles utilis s Attention Se r f rer au manuel Da...

Page 4: ...5 C 3 1 Tensions continues Gamme R solution Pr cision 600 V 0 1 V 1 2dgts Imp dance d entr e 1 M 3 2 Tensions continues Mode Peak hold Gamme R solution Pr cision 600 V 0 1 V 1 5 8dgts Imp dance d entr...

Page 5: ...lternatifs Gamme R solution Pr cision 60 A 0 01 A 2 0 5dgts 50 60Hz 3 0 5dgts 60 500Hz 600 A 0 1 A Protection 600A eff 3 8 Courants alternatifs Mode Peak hold Gamme R solution Pr cision 600 A 0 1 A 2...

Page 6: ...on d arr t automatique Polarit signe moins Indication piles faibles Tension courant alternatif Tension courant continu Mesure de courant Mesure de tension Fonction Hold Fonction Peak Hold Test de cont...

Page 7: ...arri re 1 M choires syst me de mesure de courant 2 G chette 3 Commutateur rotatif 4 Touche Peak 5 Touche du r tro clairage 6 Touche fonction Hold 7 Afficheur LCD 8 Borne COM point froid 9 Borne point...

Page 8: ...nez appuy la touche PEAK pendant plus de 2s le symbole sera affich Cette fonction permet de faire le z ro et donc de soustraire la valeur pr sente lors de l appui toutes les mesures Elle est utile en...

Page 9: ...touche Lire la valeur sur le LCD 6 3 Mesures de courant AC Positionner le commutateur sur Enserrer le conducteur mesurer dans les m choires de la pince Fermer les m choires et lire la valeur sur le L...

Page 10: ...er un offset ventuel Enserrer le conducteur mesurer dans les m choires de la pince Fermer les m choires et lire la valeur sur le LCD Note Pour effectuer une mesure de courant d branchez les cordons Si...

Page 11: ...COM Toucher la r sistance mesurer avec les pointes de touche Lire la valeur sur le LCD Note Assurez vous de toujours mesurer des composants hors tension et de d charger les capacit s ventuelles 6 6 M...

Page 12: ...mplacer les piles Arr ter votre pince en mettant le commutateur sur OFF et d branchez les cordons de mesure Retournez et ouvrez le compartiment piles avec un tournevis adapt Remplacez les 2 piles par...

Page 13: ...ec les d charges lectrostatiques 8 1 Remarques Si vous n utilisez pas votre pince pendant une dur e longue retirez les piles et assurez vous que le stockage soit effectu dans des conditions conformes...

Page 14: ...K MODE 3 3 9 RESISTANCE 3 3 10 CONTINUITY 3 4 DESCRIPTION OF THE INSTRUMENT 4 4 1 DESCRIPTION OF THE DISPLAY 4 4 2 DESCRIPTION OF FRONT AND REAR 5 5 BUTTON INSTRUCTION 6 5 1 HOLD FUNCTION 6 5 2 PEAK F...

Page 15: ...test lead Chang the battery when the symbol appears to avoid incorrect data Environmental Conditions Operation Temperature 0 C to 40 C 32 F to 104 F 70 RH Storage Temperature 10 C to 60 C 14 F to 140...

Page 16: ...x 62 x 36 mm Weight 273g with battery Accessories Carrying case Batteries Test Lead Instruction Manual 11 ELECTRICAL SPECIFICATION Accuracy is to within of the reading number of counts dgts in the ref...

Page 17: ...on Accuracy 600 A 0 1 A 2 5 8dgts 3 7 Alternating Current Range Resolution Accuracy 60 A 0 01 A 2 0 5dgts 50 60Hz 3 0 5dgts 60 500Hz 600 A 0 1 A 3 8 Alternating Current Peak Model Range Resolution Acc...

Page 18: ...tion Polarity indication Low battery indication Alternative source indication Direct source indication Current measurement indication Voltage measurement indication Data hold indication Peak data indi...

Page 19: ...ion Of Front And Rear 1 Current Sensing Clamp 2 Clamp opening handle 3 Function select dial 4 Peak button 5 Backlight button 6 Data hold button 7 LCD display 8 COM input terminal 9 Positive input term...

Page 20: ...for 2 seconds or longer the display will show symbol When you turn on this function the reading will become zero When you press on the button again the function will return to the normal mode 5 4 BAC...

Page 21: ...LCD panel 6 3 AC Current Measurement Switch the main function selector to range Open the clamp by pressing the jaw opening handle and insert the cable to be measured into the jaw Close the clamp and...

Page 22: ...nd insert the cable to be measured into the jaw Close the clamp and get the reading from the LCD panel Note Before this measurement disconnect the test lead with the meter for safety In some occasion...

Page 23: ...e points where the value of the resistance is needed Read the result from the LCD panel Note When take resistance value from a circuit system make sure the power is cut off and all capacitors need to...

Page 24: ...ymbol will appear on the LCD display and the battery needs to be changed Before changing the battery switch the main dial to OFF and disconnect test leads Open the back cover by a screwdriver Replace...

Page 25: ...the meter is not going to be used for a long time take out the battery and do not store the meter in high temperature or high humidity environment When take current measurement keep the cable at the c...

Page 26: ...BK313C 25 SEFRAM 32 rue Edouard MARTEL BP 55 F42100 SAINT ETIENNE France T l 04 77 59 01 01 Fax 04 77 57 23 23 Web www sefram fr E mail sales sefram fr...

Reviews: