INSTALLATION, OPERATION & MAINTENANCE MANUAL 

FAHRENHEIT

®

 

J-F & JX-F SERIES 

SIDE DISCHARGE  

Electric Submersible Pumps 

 

Single Phase 

115V & 230V 

 
 
 

UU

CAST IRON

UU  

UU

SINGLE PHASE

UU  

J400-F 
J750-F 

J1500-F 

J1500H-F 
 

U

316 STAINLESS STEEL

UU

SINGLE PHASE

UU  

JX400SS-F 
JX750SS-F 

JX1500SS-F 

JX1500HSS-F 

 
 
 
 
 
 
 
 
 
Read this manual carefully before installing, operating or servicing these pump models. 

UU

Observe all safety information.

UU

 Failure to comply with instructions may result in 

personal injury and/or property damage. Please retain these instructions. 
 
 

 

Summary of Contents for J-F SERIES

Page 1: ...NGLE PHASEUU J400 F J750 F J1500 F J1500H F U316 STAINLESS STEELU UUSINGLE PHASEUU JX400SS F JX750SS F JX1500SS F JX1500HSS F Read this manual carefully before installing operating or servicing these pump models UUObserve all safety information UU Failure to comply with instructions may result in personal injury and or property damage Please retain these instructions ...

Page 2: ...S BUT DOES NOT DELIVER RATED CAPACITY 14 SERVICING YOUR SUBMERSIBLE PUMP 14 MAINTAINING YOUR PUMP 14 CHANGING SEAL OIL 15 EXPLODED VIEW OF J400 F JX400SS F 16 EXPLODED VIEW OF J750 F J1500H F J1500HSS F 16 EXPLODED VIEW OF JX750SS F JX1500SS F JX1500HSS F 18 J F SERIES PARTS LIST 19 JX F SERIES PARTS LIST 21 SINGLE PHASE WIRING DIAGRAM 22 115V 230V 22 MODELS J400 F JX400 F 22 1150 230V 23 MODELS J...

Page 3: ...3 Spencer Plain Rd Old Saybrook CT 06475 USA Fax 860 399 7784 Phone 877 256 7867 Phone 860 399 5937 Information including pump data sheets and performance curves is also available on our web site HHUUwww bjmpumps comUU For assistance with your electric power source please contact a certified electrician Please pay attention to the following alert notifications They are used to notify operators and...

Page 4: ...rheated Do not operate the pump with a worn or damaged electric power cable Death or serious injury could occur Never attempt to alter the length or repair any power cable with a splice The pump motor and pump motor and cable must be completely waterproof Damage to the pump or personal injury may result from alterations After the pump has been installed make sure that the pump and all piping are s...

Page 5: ...s dents damaged threads etc 3 Check power cable and sensor cable for any cuts or damage 4 Check for and tighten any hardware that appears loose 5 Carefully read all tags decals and markings on the pump If anything appears to be abnormal contact your BJM Pumps distributor or BJM Pumps LLC If damaged the pump may need to be repaired before use Do not install or use the pump until appropriate action ...

Page 6: ...of oil J1500HSS F 10 1 300 ISO 32 NSF Food Grade Mineral Oil Note The stator on this model is oil filled This needs to be changed annually when the seal oil is changed With the power cable entry removed fill the motor chamber with oil to a level that insures the oil is covering the motor windings by and that will be above the upper bearing Do not overfill an air gap of 10 15 must be maintained for...

Page 7: ...oft ground The pump may sink preventing water from reaching the impeller Place on a solid surface or suspend the pump with a lifting rope chain The J F JX F Series pumps are provided with a suction strainer to prevent large solids from clogging the impeller Any spherical solids which pass through the strainer should pass through the pump For maximum pumping capacity use the proper size non collaps...

Page 8: ...ways to check the correct pump rotation 1 By looking at the impeller the rotation of the impeller should be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since the impeller cannot be seen the best way to check the rotation is to check the kick back motion of the pump when the pump just starts The kick back motion of the pump should be counter clockwise as sh...

Page 9: ...5m power cable NEVERUU splice the power cable due to safety and warranty considerations Always keep the lead end dry Note The single phase 115V and 230V high temperature pumps are designed to be connected directly to a proper pump control and cannot be directly plugged into a power outlet Do not alter the length or repair any power cable with a splice The pump motor and cable must be completely wa...

Page 10: ...ll load amperes UTILLISER UN DÉMARREAR APPROUVÉ CONVENANT AU COURANT Á PLEINE CHARGE DU MOTEUR BJM Pumps submersible pumps have been evaluated for use with water or water based solutions Please contact the manufacturer for additional information FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP FROM ITS POWER SOURCE BEFORE HANDLING Risk of electrical shock Do not remove power supply cable and strain reli...

Page 11: ...12 Figure 1 Single Phase 400F 115 and 750F 115 Control Figure 2 Single Phase 400F 230 750F 230 and 1500F 230 Control ...

Page 12: ... the system is properly grounded The control can be utilized as a portable control or as a permanently mounted control enclosure All Connections should be done to meet the National Electric Code and all applicable local codes and ordinances The BJM Pumps control is supplied as a manual ON OFF control A wide angle float can be wired in series with the thermal sensors to allow the pumps to operate i...

Page 13: ...uid level and position of pump 5 Excessive voltage drops due to long cables 6 Pump running backwards check rotation SERVICING YOUR SUBMERSIBLE PUMP Pump should be disconnected from the electric power supply before proceeding to do any service or maintenance The design of the F Series high temperature pump models is unique and requires specific knowledge to perform the proper assembly BJM Pumps rec...

Page 14: ...e 5 Remove screws holding the suction cover 6 Remove the suction cover 7 Remove the impeller 8 Remove the inspection screw for the oil chamber pos 50 08 Pour out a small sample of the oil If it is milky white or contains water then the oil and possible the mechanical seal should be changed If an oil change is needed 9 Remove the screws that hold the oil chamber cover in place remove the oil 10 Rep...

Page 15: ...16 EXPLODED VIEW OF J400 F JX400SS F ...

Page 16: ...17 EXPLODED VIEW OF J750 F J1500H F J1500HSS F ...

Page 17: ...18 EXPLODED VIEW OF JX750SS F JX1500SS F JX1500HSS F ...

Page 18: ... Cable w Gland 115V 1PH High Temp 204457 204454 27 Power Cable w Gland 230V 1PH High Temp 204457 204456 204454 204454 27 1 O Ring Kit Only Kit Kit Kit Kit 27 2 Seal Minder Cable High Temp 204455 204455 204455 27 2 1 O Ring Kit Only Kit Kit Kit 31D Seal Minder Probe 202409 202409 202409 202409 31E Ground Wire w Ring Term 203145 203145 203145 203145 32 Power Cord Line Clip Strain Relief 203161 20316...

Page 19: ...20 ...

Page 20: ...783 27 Power Cable w Gland 230V 1PH High Temp 202785 202784 202783 202783 27 1 O Ring Kit Only Kit Kit Kit Kit 27 2 Seal Minder Cable High Temp 201743 201743 201743 27 2 1 O Ring Kit Only Kit Kit Kit 31D Seal Minder Probe 202409 202408 202408 202408 31E Ground Wire w Ring Term 203145 203145 203145 203145 32 Power Cord Line Clip Strain Relief 203161 203161 203161 203161 33 Seal Minder Cable Line Cl...

Page 21: ...22 SINGLE PHASE WIRING DIAGRAM 115V 230V MODELS J400 F JX400 F ...

Page 22: ...23 1150 230V MODELS J750 F JX750SS F J1500 F JX1500SS F J1500H F JX1500HSS F ...

Page 23: ...winding and allow for longer pump life The sensor cable consists of four leads two are connected to the Seal Minder and two are connected to the thermal sensor switches located in the stator windings Note on 400 models the sensor and power are in a single cable These four leads run to the pump control panel and connect to the proper connections points for seal alarm and thermal cut off The black a...

Page 24: ...T IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS EXPENSE DAMAGES SPECIAL DAMAGES INCIDENTAL DAMAGES OR CONSEQUENTIAL DAMAGES ARISING DIRECTLY OR INDIRECTLY FROM THE DESIGN MANUFACTURE SALE USE OR REPAIR OF THE PRODUCT WHETHER BASED ON WARRANTY CONTRACT NEGLIGE...

Page 25: ...or Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation Use C W for clockwise CC W for counterclockwise Method used to check rotation viewed from bottom Resistance of cable and Pump Motor measured at pump control Red Black ohms Red White ohms White Black ohms Resistance of ground circuit between control panel and outside of pumps Ohms MEG OHM CHECK OF INSULATION Red...

Page 26: ...e top Yes No Control Panel MFG model no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit protection Type Number and size of short circuit device s Amp rating Overload type Size Amp rating Do protective devices comply with pump motor amp rating Yes No Are all pump connections tight Yes No I...

Page 27: ...checked for leaks Yes No Do check valves operate properly Yes No Flow Does station appear to operate at proper rate Yes No Noise level Acceptable Unacceptable Comments Describe and equipment difficulties during start up Installed by Company Person Date Maintained by Company Person Date and time of start up Present at start up Engineer s name Contractor s name Operator s name others ...

Page 28: ...NOTES ...

Page 29: ...LLC FARHENHEIT is a trademark of BJM Pumps LLC Copyright 2006 2018 BJM Pumps LLC All rights reserved BJM Pumps LLC 123 Spencer Plain Road PO Box 1138 Old Saybrook CT 06475 USA Phone 860 399 5937 Fax 860 399 7784 Email sales bjmpumps com Web Site www bjmpumps com ...