8
Lubrication:
No additional lubrication is necessary. The shaft seal and bearings are fully lubricated
from the factory. Seal oil should be checked once per year. See table: Oil Fill Quantity /
Type.
OIL FILL QUANTITY/TYPE
OIL IN SEAL CHAMBER
MODEL
U.S. FL. OZ.
CC.
TYPE OF OIL
SK08C-F
7.8
230 ISO 32 NSF Food Grade Mineral Oil
SK15C-F
7.8
230 ISO 32 NSF Food Grade Mineral Oil
SK22C-F
11.8
350 ISO 32 NSF Food Grade Mineral Oil
SK37C-F
11.8
350 ISO 32 NSF Food Grade Mineral Oil
SK55C-F
84.5
2500 ISO 32 NSF Food Grade Mineral Oil
SK75C-F
84.5
2500 ISO 32 NSF Food Grade Mineral Oil
SK110C-F
87.9
2600 ISO 32 NSF Food Grade Mineral Oil
SK150C-F
87.9
2600 ISO 32 NSF Food Grade Mineral Oil
OIL IN SEAL CHAMBER
MODEL
U.S. FL. OZ.
CC.
TYPE OF OIL
SKX08CSS-F
10.1
300 ISO 32 NSF Food Grade Mineral Oil
SKX15CSS-F
10.1
300 ISO 32 NSF Food Grade Mineral Oil
SKX22CSS-F
13.5
400 ISO 32 NSF Food Grade Mineral Oil
SKX37CSS-F
13.5
400 ISO 32 NSF Food Grade Mineral Oil
SKX55CSS-F
84.5
2500 ISO 32 NSF Food Grade Mineral Oil
SKX75CSS-F
84.5
2500 ISO 32 NSF Food Grade Mineral Oil
SKX110CSS-F
87.9
2600 ISO 32 NSF Food Grade Mineral Oil
SKX150CSS-F
87.9
2600 ISO 32 NSF Food Grade Mineral Oil
NOTE: The stator on this model is oil filled. This needs to be changed annually
when the seal oil is changed. With the power cable entry removed, fill the motor
chamber with oil to a level that insures the oil is covering the motor windings by
½”, and that will be above the upper bearing. Do not overfill, an air gap of 10-15%
must be maintained for heat expansion.
PUMP INSTALLATION
SK-F & SKX-F Series pumps have been evaluated for use with water or water based
solutions with some solids. Please contact the manufacturer for additional information.
The
BJM Pumps
Shredder Pumps (7.5 HP and larger) are designed to handle
unscreened sewage.
Summary of Contents for FAHRENHEIT SK-F Series
Page 11: ...12 Figure 1 SKX750F 115 control Figure 2 SKX750F 230 SK1500 230 and SKX1500 230 control...
Page 15: ...16 EXPLODED VIEW OF SK1500C F...
Page 16: ...17 EXPLODED VIEW OF SKX750CSS F SKX1500CSS F...
Page 19: ...20 SINGLE PHASE WIRING DIAGRAM 115V 230V MODELS SK1500CF SKX750CSS F SKX1500CSS F...
Page 25: ...NOTES...
Page 43: ...18 EXPLODED VIEW OF SK08C F SK15C F...
Page 44: ...19 EXPLODED VIEW OF SKX08CSS F SKX15CSS F...
Page 45: ...20 EXPLODED VIEW OF SK22C F SK37C F...
Page 46: ...21 EXPLODED VIEW OF SKX22CSS F SKX37CSS F...
Page 47: ...22 EXPLODED VIEW OF SK55C F SKX55CSS F SK75C F SKX75CSS F...
Page 48: ...23 EXPLODED VIEW OF SK110C F SKX110CSS F SK150C F SKX150CSS F...
Page 58: ...33...