This  Enabler  with one relay switched 

contact and powered with low voltage, is 

designed to activate elements such as 

motored doors, one-light circuit, a 

warning, the doorbell, etc. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 1: BJ Enabler 1R-LV 

 

You can activate the Enabler  remotely 

using any of the BJ System’s remote 

controllers or directly via special 

switches. 

 

 

 

 

RF Frequency

: 433MHz 

Power supply

: 12-24Vdc / 12Vac 

Output

: 1 COM relay contact 

Section of the power cables

: 1,5mm

2

 

Maximum section in load circuit

2,5mm

2

 

Dimensions: 

50x50x25mm 

Maximum loads

 

Resistive loads (light, bulbs, 

halogen lamps…): 12A 

 

Inductive loads: 

3.5A/350W/cos

ϕ

=0,4. 

 

 

 

 

 

 

 

For correct installation, the Enabler must 

be fitted in a sealed box that provides 

sufficient space, absence of dust and 

humidity and isolation from direct 

contact with people. 

 

To install the Enabler you must carry the 

Enabler’s power cable, load cable and 

switch’s cable to the box where it will be 

installed. 

 

 

 

 

For a proper installation of the device 

see figure 2: 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT:

 

See the device 

technical data to check the type and 

maximum loads that can be 

connected to the Enabler.  Power 

cables must be stripped a distance 

of 6mm. 

 

Once the Enabler’s connections are 

made and before connecting the device 

to the power supply, you must  choose 

the position on the “RF code selector” 

(see figure 1). 

 
To control the load via an alternative 

access switch, connect the two cables of 

the switch to the Control input. 

 

 
 

 

This  Enabler  is designed for switching 

devices in two selectable operating 

modes:  

12/24Vdc

Control

12 Vac

C

NA

NC

Relay output

input

RF code

Mode

operating

selector

 jumper

External switch

load control

Power supply

2. Technical data

 

3. Pre-installation

 

1. Description of the device

 

4. Installation

 

5. Operating modes

 

Power 

Supply 

input 

CAUTION!

 

Electrical installation may only 

be carried out by a qualified 

electrician! 

Do not make any unauthorized 

alterations or modifications to the 

unit. 
The relay contact is only suitable 

for 

low voltage power supply 

(12-24 V dc/ 12V ac) 
Observe the manufacturer’s 

instructions for the device to be 

operated. 

 

CAUTION!

  

An error in the connections may 

cause serious damage to the 

device or the installation, or 

harm to the operator. 

 

Operating mode 

jumper JP1 

(back side) 

RF Code 

selector 

(back side) 

Switch control 

input 

Relay 

output 