Instruction manual GLM-I
Accessories
38.019.129.001 en
457
31
31.15.1
Selecting packages to be checked
Select the packages whose bar code has to be checked. The following settings are possi-
ble:
"Off":
No code check at all.
"All packages":
The labels of all labeled packages are checked.
"With internal print":
Only labels of packages labeled by means of the internal label
printer are checked.
"Printing via channel A"
to "Printing via channel
G":
Only labels printed by the printer of the specified channel are
checked.
Mode level: 5
<Automat> / <Etc> / <Code check units> / <Code check unit1> / <Code check1>
Tap softkey with respective setting.
31.15.2
Entering evaluation time
When a label is read successfully, the code checker outputs a "Good-Read" message. If
this signal is not transmitted after reading the code, the error message "Scanner 1: Code
ilegible." is output upon expiry of the evaluation time entered here. Then the package can
be ejected, for example.
Mode level: 5
<Automat> / <Etc> / <Code check units> / <Code check unit1> /
<Scanner1: evaluation time>
Enter and confirm evaluation time in ms.
31.15.3
Entering gate width
Enter here the scanning window width (gate width).
Mode level: 5
<Automat> / <Etc> / <Code check units> / <Code check unit1> /
<Scanner1: gate width>
Enter and confirm gate width in mm.
31.15.4
Entering gate offset
Enter here the gate offset, that means the distance between the scanning window and the
front side of the package in conveying direction.
Mode level: 5
<Automat> / <Etc> / <Code check units> / <Code check unit1> /
<Scanner1: gate offset>
Enter and confirm gate offset in mm.
Summary of Contents for GLM-I
Page 410: ...Interfaces Instruction manual GLM I 408 38 019 129 001 en 30 Illustration 76 Data transmission...
Page 484: ...Appendix Instruction manual GLM I 38 019 129 001 en Illustration 123 Example of list 9...
Page 486: ...Appendix Instruction manual GLM I 38 019 129 001 en Illustration 125 Example of list 14...
Page 488: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Western Europe ASCII 144 255...
Page 489: ...Instruction manual GLM I Appendix 38 019 129 001 en Font set Eastern Europe1 ASCII 144 255...
Page 490: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Eastern Europe2 ASCII 144 255...
Page 491: ...Instruction manual GLM I Appendix 38 019 129 001 en Font set Greek ASCII 144 255...
Page 492: ...Appendix Instruction manual GLM I 38 019 129 001 en Font set Cyrillic ASCII 144 255...