SB-509-2
26
5.8
Schematic wiring diagrams OS.(A)74.-EX
Abbr
.
Component
1
Protection device P Fuchs KFD2-
GUT-Ex1.D (see operating instructions of
P Fuchs for the legend to the num-
bers inside the protection device)
OFC
Oil flow control system
B1
Oil thermostat
B2
Control unit
B3
Thermostat at the ECO suction line
F1
Main fuse
F2
Compressor fuse
F3
Control circuit fuse
F4
Oil heater fuse
F5
High pressure switch
F6
Low pressure cut-out
F7
Oil flow switch
F8
Oil level switch on the oil separator
F12
Pressure switch (ECO)
F13
Thermal overload relay “motor”
F16
Rotation direction monitoring
F17
Control transformer fuse
F18
Oil level switch of the reservoir for the oil bar-
rier
F23
Fuse of the flow direction monitoring
H1
Signal lamp “motor failure” (excess temperat-
ure/phase failure)
H3
Signal lamp “oil flow fault”
H4
Signal lamp “oil level fault”
H7
Signal lamp “wrong rotation direction”
J1
Section switch amplifier P Fuchs
KFD2-SR2-Ex1.W (1 connection) / KFD2-
SR2-Ex2.W (2 connections)
K1
Main contactor
K2
Delta contactor
K3
Star contactor
K4
Auxiliary contactor
K2T
Time relay “Pause time”
K3T
Time relay (star-delta)
K4T
Time relay “Oil level monitoring”
M1
Compressor
M3
Motor
Q1
Main switch
R1
Oil heater
Abbr
.
Component
R2
Discharge gas temperature sensor
S1
Control switch (on/off)
S2
Reset “discharge gas temperature” / “oil flow”
T1
Control transformer
T2
Voltage supply for protection device
Y1
Solenoid valve “oil injection”
Y2
Solenoid valve “liquid line”
Y3
Solenoid valve “shut-down bypass”
Y6
Solenoid valve “Capacity regulator CR1 +
CR2” (for OS.(A)7451-EX .. OS.(A)7471.-EX)
Y7
Solenoid valve “Capacity regulator CR1 +
CR2” (for OS.(A)7441-EX)
Y8
Solenoid valve “ECO” (if required)
Tab. 1: Legend for schematic wiring diagrams