SB-110-4
36
▶ In case the compressor is operated under extreme
conditions e. g. aggressive atmosphere or low out-
side temperatures: Take suitable measures. Con-
sultation with BITZER is recommended.
4.2.1
Vibration dampers
Solid mounting is possible. However, to reduce struc-
ture-borne noise, it is recommended using vibration
dampers that have been especially tuned-in to the com-
pressors (option).
!
!
NOTICE
Do not mount the compressor solidly on the
heat exchanger!
Risk of damage to the heat exchanger (fatigue
fractures).
Mounting the vibration dampers
Screws (see figure 3, page 36) are sufficiently
tightened when the upper rubber disc shows first signs
of deformation.
X
15
Fig. 3: Vibration dampers for HS.85 and HS.95 (HS.85 represented in
the figure)
Compressor
X
HS.85
M16
HS.95
M20
4.3
Connecting the pipelines
WARNING
The compressor is under pressure!
Serious injuries are possible.
Depressurize the compressor!
Wear safety goggles!