ST-150-4
59
Fig. 11: Connecting the CM-SW-01 to the BEST SOFTWARE
▶ Click the C
ONNECT
button (4).
➙ The following selection appears: BEST
CONVERTER
or
B
LUETOOTH
.
8.1.2
Selecting BEST
CONVERTER
▶ Select BEST
CONVERTER
and click the C
ONNECT
but-
ton.
➙ The compressor module is now connected to the PC
or mobile device.
▶ Select U
PDATE
F
IRMWARE
(1) and B
ROWSE
… (2).
▶ Browse the folder (...\BEST\Firmware\CM-SW-01) to
find new firmware.
▶ Start firmware update and wait until successful up-
date is confirmed. Click OK to confirm (3).
Fig. 12: Updating the firmware
8.1.3
Selecting B
LUETOOTH
▶ Select B
LUETOOTH
.
➙ A list of all available devices appears.
▶ Select the compressor.
▶ Click the C
ONNECT
button.
▶ Enter the Bluetooth password. Default setting from
firmware version 2.6.58.00: "8670", previous ver-
sions: "2"
➙ The compressor module is now connected to the PC
or mobile device.
8.2
Configuring CM-SW-01 with the BEST
SOFTWARE
In its state of delivery, the compressor module CM-
SW-01 is completely pre-configured for use with the re-
spective compressor.
Check all parameters in menu C
ONFIGURATION
and
change them if necessary. Check particularly these set-
tings:
• M
OTOR
STARTER
FUNCTION
for the time relay control of
the motor contactors
• R
EFRIGERANT
• D
ATE
• T
IME
Fig. 13: Menu C
ONFIGURATION