Trigger Input Controls
These commands control the parameters of trigger inputs.
Trigger inputs are identified using a zero-based index. Input A of the left-most trigger output is
indexed with zero.
:TRIGger:INPut:COUN?
Syntax:
:TRIGger:INPut:COUNt?
Returns the number of available trigger inputs.
Example query:
TRIG:INP:COUN?
Example response:
2
:TRIGger:INPut#:IDENtifier?
Syntax:
:TRIGger:INPut#:IDENtifier?
Returns the unique identifier for this trigger input. This identifier is required when defining events
(see page 59), or when defining a triggered sequence start condition (see page 42).
Example query:
TRIG:INP0:IDEN?
Example response:
"TRIGGER0"
:TRIGger:INPut#:TERMinated
Syntax:
:TRIGger:INPut#:TERMinated <bool>
Enables or disables the termination relay for this trigger input.
Example command:
TRIG:INP0:TERM ON
:TRIGger:INPut#:TERMinated?
Syntax:
:TRIGger:INPut#:TERMinated?
Returns the current state of the termination relay for this trigger input.
Example query:
TRIG:INP0:TERM?
Example response:
1
:TRIGger:INPut#:THReshold
Syntax:
:TRIGger:INPut#:THReshold <threshold>
Sets the threshold level, in volts, for this trigger input.
Example command:
TRIG:INP0:THR -300e-3
54
BitifEye Digital Test Solutions GmbH