Bird 4421 RF Power Meter
38
Status
(Ux)
Function
Reads a status word and returns the information as a string. Set x to:
Remarks
After sending the status command, a status word is sent the next time the
unit is addressed to talk. To ensure the correct status is transmitted, the sta-
tus word should be requested as soon as possible after the command is sent.
Machine Status Word (U0):
The format of the machine status word is
sh own in F igu r e 32. Th e defa u lt va lu es a r e a lso sh own .
Error Status Word (U1):
The format of the error status word and the possi-
ble error messages are shown in F igu r e 33. All fla gs will r ever t t o t h eir n on -
error states after the U1 command is sent.
Figure 32
Machine Status
Word Format
Note:
This command sets the unit to the settings that were last issued
remotely (through RS-232 or GPIB). Therefore, it will over ride any manual
changes selected at the front panel of the unit.
Header
Measurement Function
Range
Prefix
Terminator
Trigger
XON / XOFF
TERM
0
C
R
Y
Y
P
Y
Y
T
T
1
X
0
Figure 33
Error Status
Word Format
Header
Command Status (shown valid)
Command Option Status (shown valid)
Self-test results (shown fail)
TERM
4
0
V
C
M
V
C
0
F
L
Status
Meaning
Description
ICM
Invalid Command
Set wh en a n illega l device-depen den t
com m a n d (IDDC) su ch a s V2 is
r eceived. (V is illega l)
VCM
Valid Command
Set wh en n o IDDC is r eceived.
ICO
Invalid Command
Option
Set wh en a n illega l device-depen den t
com m a n d opt ion (IDDCO) su ch a s T6 is
r eceived. (6 is illega l)
Summary of Contents for THRULINE 4020 series
Page 2: ...This page intentionally left blank...
Page 16: ...Bird 4421 RF Power Meter 4 Figure 4 Power Sensor Outline Drawing 4028C Series only...
Page 18: ...Bird 4421 RF Power Meter 6 4028 Series...
Page 22: ...Bird 4421 RF Power Meter 10...
Page 40: ...Bird 4421 RF Power Meter 28...
Page 52: ...Bird 4421 RF Power Meter 40...
Page 72: ...Bird 4421 RF Power Meter 60...