Chapter 4
Operating Instructions, No Blower
Normal Operation
Bird 889x–300 loads have no indicators or operating controls. They require no
special operating procedures or surveillance when their performance limits are
not exceeded. Follow the instructions for the specific transmitter equipment.
Operating Under Abnormal Conditions
The load can be subjected to moderate overloads for short periods.
Shutting Down
These loads are passive devices, so have no way of being turned off. Turn off
RF power at the source.
Emergency Shutdown
Turn off RF power at the source.
Note:
If the interlock thermoswitch is properly connected, RF
power will be automatically turned off when the coolant temperature
reaches an unsafe level.
CAUTION
Make sure the interlock is properly connected when overloaded to prevent
damage to the load.
WARNING
Never attempt to connect or disconnect RF equipment from the transmission
line while RF power is being applied. Leaking RF energy is a potential
health hazard.