64
Reflected DAC Gain —
The BPME has an linear analog output voltage of 0-2
VDC representing the full scale of the reflected power. The Reflected DAC Gain
setting allows the adjustment of the value the voltage represents. This allows for
increased resolution at lower power levels.
1 - 2 VDC = Full Power
2 - 2 VDC = 1/2 Full Power
4 - 2 VDC = 1/4 Full Power
8 - 2 VDC = 1/8 Full Power
Note:
If the reflected full scale of the BPME is 250 mW to 25 W.
If 1 is selected for the DAC Gain the 2 VDC output would be the
equivalent of 25 W.
If 2 is selected for the DAC Gain the 2 VDC output would be equivalent
of 12.5 W.
Alarm Latch Enable —
When enabled, alarms must be manually reset.
When disabled alarms will automatically reset after approximately 40 seconds.
VSWR Alarm on Zero Enable —
When enabled, VSWR will alarm at low
power (less than 2.5% of full scale) due to noise floor the sensor. When disabled,
VSWR is NOT monitored at very low power levels (less than 2.5% of full scale).
Power Up Alarm Enable —
When enabled, the BPME will be in alarm
condition on power on until first power measurements are made. When
disabled, BPME will not set an alarm at power on.