background image

i

Safety Precautions

The following are general safety precautions that are not necessarily related to 
any specific part or procedure, and do not necessarily appear elsewhere in this 
publication. These precautions must be thoroughly understood and apply to all 
phases of operation and maintenance.

WARNING

Keep Away From Live Circuits

Operating Personnel must at all times observe general safety precautions. Do 

not replace components or make adjustments to the inside of the test 

equipment with the high voltage supply turned on. To avoid casualties, 

always remove power.

WARNING

Shock Hazard

Do not attempt to remove the RF transmission line while RF power is present.

WARNING

Do Not Service Or Adjust Alone

Under no circumstances should any person reach into an enclosure for the 

purpose of service or adjustment of equipment except in the presence of 

someone who is capable of rendering aid.

WARNING

Safety Earth Ground

An uninterruptible earth safety ground must be supplied from the main 

power source to test instruments. Grounding one conductor of a two 

conductor power cable is not sufficient protection. Serious injury or death 

can occur if this grounding is not properly supplied.

WARNING

Resuscitation

Personnel working with or near high voltages should be familiar with modern 

methods of resuscitation.

WARNING

Remove Power

Observe general safety precautions. Do not open the instrument with the 

power applied.

Summary of Contents for 4044 Series

Page 1: ...l Power Sensor Model 4044 Series Operation Manual Copyright 2019 by Bird Technologies Inc Instruction Book Part Number 920 4044 Rev D Thruline and Termaline are registered trademarks of Bird Electroni...

Page 2: ...remove the RF transmission line while RF power is present WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of service or adjustm...

Page 3: ...rocedure which if not correctly performed could result in personal injury CAUTION Caution notes call attention to a procedure which if not correctly performed could result in damage to the instrument...

Page 4: ...E SEGURIDAD DEL INSTRUMENTO BENUTZUNG WIRD DAS GER T AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN KANN DIE GER TESICHERHEIT BEEINTR CHTIGT WERDEN UTILISATION TOUTE UTILISATION DE CET INST...

Page 5: ...S GER TES GELTEN NUR F R GESCHULTES FACHPERSONAL ZUR VERMEIDUNG GEF HRLICHE ELEKTRISCHE SCHOCKS SIND WARTUNGSARBEITEN AUSSCHLIE LICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUF HREN ENTRENTIEN L EMPLO...

Page 6: ...cally updated When inquiring about updates to this manual refer to the part number and revision on the title page Chapter Layout Introduction This section provides a general description of the 4044 Se...

Page 7: ...ety Statements iii About This Manual v Changes to this Manual v Chapter Layout v Chapter 1 Introduction 1 Chapter 2 Installation 2 Power Sensor Installation 3 Chapter 3 Maintenance 4 Customer Service...

Page 8: ...h an overall range of 144 to 960 MHz See Model Identification on page 7 for specific frequency ranges and model features Figure 1 Bird 4044 Series Power Sensor Features Input RF connector N Type femal...

Page 9: ...rs are designed to be used for continuous power monitoring in multiple Land Mobile Radio LMR systems When used with the Bird CPM the 4044 can provide real time RF power measurements Figure 2 Connectio...

Page 10: ...tput cable to the 4044 RF input 3 Connect 4044 s RF output connector to the Combiner input 4 Repeat step 1 through 3 for any additional 4044 power sensors 5 Connect a data power cable from the CPM to...

Page 11: ...d be referred to a qualified service center If the unit needs to be returned for any reason request an Return Material Authorization RMA through the Bird Technologies website All instruments returned...

Page 12: ...mpedance 50 Ohm Insertion Loss 0 1 dB Insertion VSWR 1 10 1 Instrument Interface 0 to 4 VDC via RJ25 Jack Interface Connections RF Connectors Input Output Type N male or Type 4 3 10 male Type N female...

Page 13: ...ill be reflected back to the source The non directional power sensor does not differentiate between forward and reflected power so any mismatch will impact the measurement The larger the reflected ene...

Page 14: ...Non Directional Power Sensor 7 Model Identification 0 1 2 34 5 0 6 0 7 8 6 0 7 9 567 8 9 567...

Page 15: ...such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten 10 days from the date of discovery of the defect The above warranties shall not exten...

Page 16: ......

Reviews: