1
RFGate
3.2.T
50
121
23
106
22
4
4
ON
1 2
1 2
ON
1
2
ON
1 2
ON
1 2
ON
1 2
ON
IN1
IN2
*
IN1
IN2
*
8k2
8k2
IN1
IN2
*
8k2
8k2
IN1
IN2
*
8k2
2x = NC
4x = NO
NC
NO
i
1
2
i
LED
i
50
125
23
106
22
ON
1 2
Transmitter for safety edges to RFGate 3 wireless signal transmission system
Supplementary sheet to the original instruction manual
General
1
Safety instructions
ENGLISH
370058C
07/19
Transmitter
Option with connector for
external antenna
Battery life up to 2 years, but it is recommended batteries are changed every 12 months.
Intended use: In combination with a receiver RFGate 3.x.R
Batteries
CR2032
DIP-
switch
Push
button
On the transmitter:
= safety edge
= switch (NO or NC: see 2.2)
DIP switch setting according to sensors
(safety edge, switch contact)
2.1 DIP switch setting
*
IN2 is only active when used with dual channel receiver RFGate 3.2.R with DIP switch 2 OFF
2.2 How to change inputs from NC to NO (factory setting = NC)
1.
Insert first
battery
4.
Insert 2
nd
battery
2.
Status
3.
Change
5.
Change stored
Press button on
transmitter
Status
changes
LED
flashes
LED flashes
> 1.5 sec.
After inserting the first battery,
you have 10 seconds to change the logic.
2
Wiring / set-up
Conductor cross section 0.25 – 0.75 mm
2
on RFGate 3.2.R