Parameter
Direction recognition
Field size
Relay hold interval
SMD function
Mounting height
Cross traffic
Interference suppression
SMD field size
Field geometry
C
1
+ *
+
C
2
+
C
3
+
C
4
+
C
5
+
C
6
Standard
ON, forwards
6
1 s
Off
Up to 3 m
Low
Off
1
Wide
C
1
Pavement
ON, forwards
7
0.8 s
Off
Up to 3 m
Medium
Off
1
Narrow
C
2
Retirement home
OFF
6
2 s
Decreasing, 2 s
Up to 3 m
Off
Off
5
Wide
C
3
Entry hall
ON, forwards
6
0.2 s
Off
Up to 3 m
Low
Off
1
Narrow
C
4
Supermarket
ON, forwards
9
1.5 s
Decreasing, 2 s
3-4 m
Off
Off
5
Wide
C
5
High mounting
ON, forwards
9
1 s
Off
3-4 m
Medium
Off
1
Wide
C
6
3 m
(9.84')
>
Key code
Enhanced functions
B
D
+
F
1
+
F
3
+
F
4
+
F
5
+
F
6
+
F
7
+
F
8
Recommendation:
First, select the enhanced function that is closest to the requirements and then change the parameter levels correspondingly.
* Factory setting
A
1
ca. 15 min.
A
2
A
3
Keep the door open manually for
15 min. when making the settings.
Afterwards the door will close when
there is no object within the detection
area.
Door closes when no object is in the
detection area; afterwards standard
operation.
Configuration mode is ended; door clo-
ses when no object is in the
detection area; afterwards standard
operation.
In order to prevent the door from opening and closing unnecessarily while the parameters are being set or changed, it can be held open or closed again with the function.
5.2.6
Setting / changing parameters
RE
GLO
beam
G
RE
GLO
beam
4 x 9
4x
Press
→
light up, i.e. the “access
code” function is activated
(the code has been stored)
Press
four times
Confirm by pressing
→
light up, i.e. the “access
code” function is deactivated
(the code is reset)
Establish the connection
(chap. 5.2.3)
RE
GLO
beam
C
RE
GLO
beam
C
9
+
Deactivating the access code (reset code)
The code can only be reset if the sensor is already in configuration mode.
RE
GLO
beam
G
RE
GLO
beam
Code
4x
Press
→
light up, i.e. the “access
code” function is activated
(
→
If light up, the “access
code” function is deactivated)
Enter a 4-digit code.
Confirm by pressing
→
light up, i.e. the configura-
tion mode is activated and the
sensor is ready for programming
(
→
If light up, the code was
incorrect; restart at 1)
Establish the connection
(chap. 5.2.3)
RE
GLO
beam
C
RE
GLO
beam
C
9
+
Activating the configuration mode via the access code
The configuration mode can only be activated with the remote control, if a code was previously stored and the “access code” function is activated.
Deactivating the access code without the remote control
Press both [<] and [>] keys simultaneously for 8 s.
Caution:
All parameters are reset to the default settings!
+