CareMat
with 868.8 MHz TeleAlarm
®
radio transmitter
Translation of the original instructions
The pressure-sensitive bed mat for dementia
patients and persons at risk of falling
1
Safety instructions
2
Product description
The CareMat with 868.8 MHz TeleAlarm
®
radio transmitters are operated in con-
junction with compatible radio receivers from the NurseCall 8 program of the
manufacturer TeleAlarm SA (www.telealarm.com). In care facilities, the radio re-
ceivers are usually paired with an existing call system infrastructure. When the
mat is activated, the call system infrastructure emits an alarm signal.
2.2
Areas of application and function
The CareMat was primarily designed for use in retirement and nursing
homes, hospitals and psychiatric wards as well as for sheltered residential
accommodation. The necessary care and supervision of patients with dementia
and of those who are at risk of falling represents a significant increase in care
expenditure for care practitioners. The CareMat is the ideal support: risks of
falling and the dangers which arise from wandering or loss of orientation can
be significantly reduced.
The CareMat as a pressure-sensitive sensing device is laid directly in front
of the care bed or the door to the room. As soon as the person leaves the
bed and steps onto the CareMat, this switches on and sends out an alarm
signal to the call system via the radio receiver. The wireless signalling
system reduces the risk of falling caused by wiring on the floor.
Should the CareMat not be needed,
it can be pushed underneath the bed.
Align the CareMat centrally in front of
the bed with the handles underneath
the edge of the bed so that missing
the mat is impossible.
TeleAlarm
®
radio receiver paired
with the call system (observe radio
receiver operating instructions)
• During transport and storage, any significant bending of the
CareMat should be avoided.
• Store the CareMat in a dry, clean and flat location at 0 °C to +55 °C.
• Do not place any heavy loads on the CareMat and do not stack more
than 10 mats on top of each other.
• The CareMat can be cleaned using commercially available disinfecting
and cleaning agents with max. 70 vol% alcohol. No corrosive agents
should be used.
• The CareMat is neither autoclavable nor can it be disinfected using
steam.
3
Day-to-day operation
4
Cleaning and disinfecting
5
Transport and storage
2.1
Radio system description
Housing with radio transmitter
Chamfered, wheelchair-accessible edges
Non-slip surface with stud texture design
1
2
3
Handles
Switching active zone
Radio receiver: NOT included
4
5
6
1
2
1
1
2
2
3
3
3
4
4
4
4
4
5
5
5
CareMat A01T T868.8
CareMat A11T T868.8
1100 x 700 mm
CareMat B01T T868.8
CareMat B11T T868.8
700 x 400 mm
CareMat C01T T868.8
CareMat C11T T868.8
1100 x 700 mm,
half round
DE
EN
FR ES
IT SV
443160A
02/22
• Read these operating instructions thoroughly before putting the device into operation
and keep them for future reference.
• Not a safety component in accordance with the EU Machinery Directive must not be
used for personal protection or EMERGENCY STOP function.
• Do not use this product other than for its specified application.
• Failure to follow these safety precautions may cause damage to device or objects, se-
rious personal injury, or death.
• Observe all applicable local, national, and international safety standards,
codes, and laws.
• After accessing the inside of the device, ensure the cover/protection seal is closed
tightly to achieve designated protection rating.
• Warranty claims will be invalid in the event of any damage to the product, to goods or
persons that is due to failure to observe these instructions.
Instructions for nursing staff
• The CareMat operates purely as a support for the nursing staff, but is not a substi-
tute for them.
• The functionality of the CareMat is to be checked each time that it is used.
Notes for the installer
• This CareMat may only be operated together with compatible radio receivers from
the NurseCall 8 program of the manufacturer TeleAlarm SA.
• The electrical installation work and commissioning of the product may only be
carried out by a qualified technician.
• Avoid touching any electronic components.
• ESD safety rules should be observed.
6