Birch BD-408e Manuals Download Page 1

NOTICE

This equipment has been tested and found comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interface when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interface to radio
communications. Operation of this equipment in a residential area is
likely to cause harmful interface in which case the user will be
required to correct the interface at his own expense.

*

 

All brand and trademark are belonged to their respective owner.

*

 

Specifications are subject change without notice.

This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
condition: (1) This device may not cause
harmful interface, and (2) This device must
accept any interface received, including
Interface that may cause undesired operation.

1

Summary of Contents for BD-408e

Page 1: ...uction manual may cause harmful interface to radio communications Operation of this equipment in a residential area is likely to cause harmful interface in which case the user will be required to corr...

Page 2: ...Operation Manual 2...

Page 3: ...OCIA 20 3 System Control 21 4 Code Option 26 UPC A 26 UPC E 28 EAN 13 ISBN ISSN 30 EAN 8 32 CODE 39 CODE 32 34 Interleaved 2 of 5 Odd S code 36 Industrial 2 of 5 38 Matrix 2 of 5 40 China Post 2 of 5...

Page 4: ...of scanner after reading EXIT label There are recommended steps as follows 1 Set right host interface for your scanner at 10 The scanner is in factory default as bold label 2 Set interface to optimiz...

Page 5: ...alue Setting Select Function Label Interface Default Exit Interface Default Function PROGRAM Decimal 10 s Value Hexdecimal High Byte Decimal 1 s Value Hexdecimal Low Byte SET EXIT ABORT VERSION DATE S...

Page 6: ...Loudness 05 Level 5 Beep Tone 24 2 4 KHz Beep Duration 06 60 mSec Beep Tone1 12 1 2 KHz Beep Duration1 06 60 mSec Stand by Time 15 15 Sec Active Time 20 200 mSec Sleep Time 20 200 mSec Good read Dela...

Page 7: ...4 Truncate Leading Ending The leading or ending digits of barcode data characters can be truncated when these values are set to non zero It will be read nothing else only beeps when the truncate valu...

Page 8: ...n unknown label but read manual very well A Refer to code name at 64 to set Enable read a barcode label then you will know what symbology is read Beside it maybe need to verify checksum Refer to verif...

Page 9: ...ext to the selection description you will find a frame command such as AAB These commands can be sent to scanner with RS 232C interface You must make sure that scanner is the same protocal as your equ...

Page 10: ...to excute a text editor program such as PE2 and Word for keyboard interface or excute a terminal program such as Hyper Terminal for RS 232 Then scanner will transmit current settings on screen ABORT I...

Page 11: ...and Refer to ASCII table 71 at grey area You ll find function keys with ASCII codes The Keypad have to selecte if your application program is only keypad numeric code acceptable So scanner will output...

Page 12: ...ission speed is too high the system may not be able to receive all characters Adjust it and try out suited delay to makes system work properly Transmit Delay It is a delay timer between barcode data o...

Page 13: ...e converter Refer to Cable Type at 66 IBM AT PS 2 DFA DFA IBM XT DFB DFB Macintosh ADB DFC DFC IBM PS 2 25 30 DFD DFD NEC 9801 DFE DFE IBM PS 2 55 DFF DFF IBM 5550 DFG DFG KT 106 DFH DFH IBM 5576 DFI...

Page 14: ...INDOWS entry Control then pop Keyboard to selecte country at language item For details please refer to your DOS or WINDOWS user s manual DGA USA US DGA DGB Belgium BE DGB DGC Danish DK DGC DGD France...

Page 15: ...ransmit data upon receiving active CTS signals Data Ready The scanner will active the RTS signal to indicate a successful decoding and will transmit data upon receiving CTS signals STX ETX The STX and...

Page 16: ...Bps DHA DHB 19200 Bps DHB DHC 9600 Bps DHC DHD 4800 Bps DHD DHE 2400 Bps DHE DHF 1200 Bps DHF DHG 600 Bps DHG DHH 300 Bps DHH DKA None DKA DKC Even DKC DKD Odd DKD DKE Space DKE DKF Mark DKF PROGRAM...

Page 17: ...omputer If scanner doesn t get any acknowledgments form host after the timeout occurs it will issue 5 warning beeps You may check handshanking mode or adjust a longer delay timer The feature is partic...

Page 18: ...ur wand decoder resolution The unit of speed is a width of minimum narrow bar Output Speed Bps bits per second Low 1200 Medium 2400 High 4800 Turbo 9600 The setting is applied two kinds of ratio barco...

Page 19: ...t them Margin Delay It is a timer of zone like space zone of barcode label margin The width of margin time will be added before and after in each barcode data automatically when it is transmitted Tran...

Page 20: ...a output It is also the same as Transmit Delay of keyboard wedge see 12 DSA NCR DSA DSB DTS DSB DSC NCR ASCII DSC DSD DTS ASCII DSD DSE ASCII DSE DTA Even DTA DTB Odd DTB DTC Space DTC DTD Mark DTD DU...

Page 21: ...ess Tone and D uration are adjustable by setting of Specific Adjustment at 24 The scanner will operate in Power Saving mode as this function is Enabled Current will be reduced to less than 20 mA but s...

Page 22: ...arcode The scanner can read many sets of barcode data on the same scanning line at the same time even they are different kinds of barcode symbology The direction of read out is form left to right Refe...

Page 23: ...ration elapsed This mode can save the power resource and extend the operation life of the light source The scanner can be waked up when there is a successful reading or trigger button to be pressed Co...

Page 24: ...imeout The Action Time is lighting duration and the Sleep Time is blanking duration while light source flashing The barcode can also be read during flashing of light source and then waked up the scann...

Page 25: ...in Max Length Public Minimum and Maximum length can be set to qualify data entry They are effect all symbologies if their Min Max Code Length is zero The length is defined to the actual barcode data l...

Page 26: ...5 It is recommended to set Enable if the WPC with Add on code must be read together You have to enable it first and refer to Add on Waiting Time at 24 for good reading of Add on By setting Enable chec...

Page 27: ...to the data begin or tail transmitted if the feature is selected There are some symbobolgies i e UPC E and EAN 8 include 2 Code IDs If your application want to transmit Code ID you must set Code ID T...

Page 28: ...n function is used only for UPC E and EAN 8 code reading It extends to 13 digits with 0 digits when the feature is enabled Example Barcode 01236547 Output 0012360000057 ECA Disable ECA ECB Enable ECB...

Page 29: ...R BAR Range 0010 1510 Code ID1 AAB AAB Range 0016 FF16 ASCII Code Code ID2 AAC AAC Range 0016 FF16 ASCII Code Insertion Group BDD BDD Range 0010 9910 Specific Adjustments Disable EIA EIA Enable EIB EI...

Page 30: ...kinds of barcode for book and magazine The ISBN is 10 digits with leading 978 and the ISSN is 8 digits with leading 977 of the EAN 13 symbobolgy Example Barcode 9879572222720 Output 9572222724 Example...

Page 31: ...te Leading BAS BAS Range 0010 1510 Truncate Ending BAT BAT Range 0010 1510 Code ID AAD AAD Range 0016 FF16 ASCII Code Insertion Group BDE BDE Range 0010 9910 Specific Adjustments Check Digit Transmiss...

Page 32: ...rmat Data Digits 7 Digits Check Digit Add on 2 or 5 Refer to 26 Refer to 28 ESA Disable ESA ESB Enable ESB ETA Disable ETA ETB Add on 2 Only ETB ETC Add on 5 Only ETC ETD Add on 2 or 5 ETD EUA Disable...

Page 33: ...ge 0010 1510 Truncate Ending BAV BAV Range 0010 1510 Code ID1 AAE AAE Range 0016 FF16 ASCII Code Code ID2 AAF AAF Range 0016 FF16 ASCII Code Insertion Group BDF BDF Range 0010 9910 Specific Adjustment...

Page 34: ...Code 39 are V You can transmit all data digits including two V This function which allows several symbols to be concatenates and be treated as one single data entry The scanner will not transmit the e...

Page 35: ...ting is no greater than the Maximum length setting or all the labels of the symboblogy will not be read In particular you can set the same value for both Minimum and Maximum reading length to force th...

Page 36: ...ntains an even digits If the symbol is present an odd number as S code then Odd S code have to select The checksum is made as the sum module 10 of the numberical values of all data digits Refer to 35...

Page 37: ...ngth it is like a length filter and only one length is accepted Refer to 27 35 Truncate Leading BBC BBC Range 0010 1510 Truncate Ending BBD BBD Range 0010 1510 Min Code Length BBA BBA Range 0010 5610...

Page 38: ...Checksum Optional The checksum is made as the sum module 10 of the numberical values of all data digits Refer to 35 FQA Disable FQA FQB Enable FQB FSA Disable FSA FSB Enable FSB FTA Disable FTA FTB E...

Page 39: ...te Ending BBH BBH Range 0010 1510 Min Code Length BBE BBE Range 0010 5610 Max Code Length BBF BBF Range 0010 5610 Code ID AAI AAI Range 0016 FF16 ASCII Code Insertion Group BDI BDI Range 0010 9910 Spe...

Page 40: ...le Checksum Optional The checksum is made as the sum module 10 of the numberical values of all data digits Refer to 35 FVA Disable FVA FVB Enable FVB FXA Disable FXA FXB Enable FXB FYA Disable FYA FYB...

Page 41: ...cate Ending BBL BBL Range 0010 1510 Min Code Length BBI BBI Range 0010 5610 Max Code Length BBJ BBJ Range 0010 5610 Code ID AAJ AAJ Range 0016 FF16 ASCII Code Insertion Group BDJ BDJ Range 0010 9910 S...

Page 42: ...Checksum Optional The checksum is made as the sum module 10 of the numberical values of all data digits Refer to 35 GAA Disable GAA GAB Enable GAB GCA Disable GCA GCB Enable GCB GDA Disable GDA GDB E...

Page 43: ...fer to 27 35 Truncate Leading BBO BBO Range 0010 1510 Truncate Ending BBP BBP Range 0010 1510 Min Code Length BBM BBM Range 0010 5610 Max Code Length BBN BBN Range 0010 5610 Code ID AAK AAK Range 0016...

Page 44: ...cation Sometime the Codabar requires only same Start End patten of barcode label to be decoded Refer to 34 The checksum is made as the sum module 16 of the numberical values of all data digits GFA Dis...

Page 45: ...ading BBS BBS Range 0010 1510 Truncate Ending BBT BBT Range 0010 1510 Min Code Length BBQ BBQ Range 0010 5610 Max Code Length BBR BBR Range 0010 5610 Code ID AAL AAL Range 0016 FF16 ASCII Code Inserti...

Page 46: ...o be a concatenation code as GS 7F16 C1 Datas GS Datas Checksum This function which allows several symbols to be concatenates and be treated as one single data entry The checksum is presented as the s...

Page 47: ...BBW Range 0010 1510 Truncate Ending BBX BBX Range 0010 1510 Min Code Length BBU BBU Range 0010 5610 Max Code Length BBV BBV Range 0010 5610 Code ID AAM AAM Range 0016 FF16 ASCII Code UCC EAN 128 ID AB...

Page 48: ...ows several symbols to be concatenates and be treated as one single data entry The checksum is presented as the sum module 47 of all data digits Refer to 35 GTA Disable GTA GTB Enable GTB GVA Disable...

Page 49: ...runcate Ending BCB BCB Range 0010 1510 Min Code Length BBY BBY Range 0010 5610 Max Code Length BBZ BBZ Range 0010 5610 Code ID AAN AAN Range 0016 FF16 ASCII Code Insertion Group BDN BDN Range 0010 991...

Page 50: ...um is presented as the sum module 11 of all data digits By setting Enable checksum1 and checksum2 will be transmitted upon your selected checksum verificvation mothod GZA Disable GZA GZB Enable GZB HB...

Page 51: ...runcate Ending BCF BCF Range 0010 1510 Min Code Length BCC BCC Range 0010 5610 Max Code Length BCD BCD Range 0010 5610 Code ID AAO AAO Range 0016 FF16 AscII Code Insertion Group BDO BDO Range 0010 991...

Page 52: ...The checksum is presented 3 kinds of mothod Mod 10 Mod 10 10 and Mod 11 10 The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits Refer to 50 HEA Disable HEA HEB...

Page 53: ...ncate Ending BCJ BCJ Range 0010 1510 Min Code Length BCG BCG Range 0010 5610 Max Code Length BCH BCH Range 0010 5610 Code ID AAP AAP Range 0016 FF16 ASCII Code Insertion Group BDP BDP Range 0010 9910...

Page 54: ...sum Verification Spare Function Format Data Digits Variable Checksum1 2 Optional Refer to 35 HSA Disable HSA HSB Enable HSB HTA Disable HTA HTB Enable HTB HQA Disable HQA HQB Enable HQB HRA Disable HR...

Page 55: ...uncate Ending BCR BCR Range 0010 1510 Min Code Length BCO BCO Range 0010 5610 Max Code Length BCP BCP Range 0010 5610 Code ID AAR AAR Range 0016 FF16 ASCII Code Insertion Group BDQ BDQ Range 0010 9910...

Page 56: ...onal Air Transport Association The checksum is presented as sum module 7 of all data digits Refer to 35 HJA Disable HJA HJB Enable HJB HNA Disable HNA HNB Enable HNB HOA Disable HOA HOB Enable HOB HKA...

Page 57: ...Truncate Ending BCN BCN Range 0010 1510 Min Code Length BCK BCK Range 0010 5610 Max Code Length BCL BCL Range 0010 5610 Code ID AAQ AAQ Range 0016 FF16 ASCII Code Insertion Group BDR BDR Range 0010 9...

Page 58: ...both formats inside barcode label of Telepen By setting Auto Switching datas can be conversed between Numeric and Full ASCII by character DLE 7F16 automatically Refer to 35 HVA Disable HVA HVB Enable...

Page 59: ...runcate Ending BCV BCV Range 0010 1510 Min Code Length BCS BCS Range 0010 5610 Max Code Length BCT BCT Range 0010 5610 Code ID AAS AAS Range 0016 FF16 ASCII Code Insertion Group BDS BDS Range 0010 991...

Page 60: ...eturn character to finish data transmitted or you may set the Postamble Transmission to be D isable for your applicationno without any control characters apppended after data transmitted The factory d...

Page 61: ...t is Enable Refer to String Output Flowchart at 5 Example Append a string ABCD after each barcode transimitted 1 PROGRAM Entry Programming 2 Enable Enable Suffix Transmission 3 D ata 4 1 4 2 4 3 4 4 S...

Page 62: ...tion Beside make sure insertion positions are not greater than the symbols otherwise the insertion datas are no effect ABD Data1 ABD Range 0016 FF16 ASCII Code ABE Data2 ABE Range 0016 FF16 ASCII Code...

Page 63: ...AB 345 CD 67 6 I nsert Group 0 1 SET Insertion1 only or I nsert Group 1 0 SET Output 12 AB 34567 6 I nsert Group 1 1 SET Insertion1 outopt twice Output 12 AB AB 34567 6 I nsert Group 0 0 SET insertio...

Page 64: ...ted The total length is a number of barcode datas except Truncate Leading Ending Digits And the length has two digits This function is useful to show unknown barcode symbologies which include all read...

Page 65: ...r call inverse barcode This function is optional for some special models Last barcode data can re send with trigger It s only for Timeout Off Timeout Flash and Continue scanning mode during the light...

Page 66: ...in M 5p Din F 5p Mini Din M 6p Mini Din F Macintosh Function 4p Mini Din M 4p Mini Din F RST Host 2 2 Data Host 1 1 Ground 4 4 GND Shield 4 4 VCC 5V 3 3 2 4 1 3 1 3 2 4 4p Mini Din M 4p Mini Din F NEC...

Page 67: ...D Sub F 8p Din M 2 1 DC Jack M Wand Emulation Function 9p D Sub F 5p Din M 6p Din M Data 2 2 2 Ground 7 3 3 GND Shield 8 3 3 VCC 5V 9 1 1 9 5 1 6 1 2 3 4 5 1 2 3 4 5 6 9p D Sub F 5p Din M 6p Din M TTL...

Page 68: ...2 2 1 6 6 7 5 0 0 4 2 0 ISBN 9572216678 Code 39 Full ASCII Code C O D E 3 9 T E S T Full ASCII Code CODE39 Test Interleaved 2 of 5 1 2 3 4 5 6 7 8 9 0 5 Code 93 C O D E 9 3 T E S T Y d Code 128 C Type...

Page 69: ...5 D D 4 3 2 1 0 A MSI Plessey 1 0 5 5 8 3 0 2 5 CODE 11 8 8 6 2 6 4 7 7 7 9 7 3 3 UK Plessey 1 6 5 2 0 0 0 3 5 4 6 1 Telepen T E L E P E N T e s t Numeric 57424942534251055774888916 IATA 0 0 1 0 2 0 0...

Page 70: ...Operation Manual 70...

Page 71: ...C C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US n For keyboard wedge only L H 2 3 4 5 6 7 0 SP 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v...