114
|
english
Terminal
Type
Function
NC
Normally closed contact
Signal relay 1
(LIVE or SELV)
C1
Common
NO
Normally open contact
NC
Öffner
Signal relay 2
(SELV only)
C2
Gemeinsamer Leiter
NO
Schließer
10
DI3/OC1
Digital input/output, configurable.
Open collector: Max. 24 V resistive or inductive.
4
AI1
Analog input: 0-20 mA / 4-20 mA
0,5 - 3,5 V / 0-5 V / 0-10 V
2
DI1
Digital input, configurable
DI1 = Start / Stop
5
+5 V
Supply to potentiometer and sensor
6
GND
Ground
A
GENIbus, A
GENIbus, A (+)
Y
GENIbus, Y
GENIbus, GND
B
GENIbus, B
GENIbus, B (-)
3
GND
Ground
15
+24 V
Supply
8
+24 V
Supply
26
+5 V
Supply to potentiometer and sensor
23
GND
Ground
25
GDS TX
Grundfos Digital Sensor output
24
GDS RX
Grundfos Digital Sensor input
7
AI2
Analog input: 0-20 mA / 4-20 mA / 0,5 - 3,5 V /
0-5 V / 0-10 V