BioSmart UniPass
Installation Guide
www.biosmart-tech.com
Page 1: ...BioSmart UniPass Installation Guide www biosmart tech com ...
Page 2: ...Ds and jumpers 4 Connector names and description 5 2 Installation 6 Cable types 6 General installation notes 6 Mounting on wall 6 Mounting on DIN rail 7 Power supply connection 7 Network connection 8 PV WM Readers connection 8 Fail safe lock connection 9 Fail secure lock connection 10 Exit buttons and door sensors connection 11 Wiegand connection 11 ...
Page 3: ...lowed properly before putting the unit into operation Do not turn on the power supply until all installation procedures are finished this may lead to injury or equipment damage Do not disconnect or connect cables while unit is powered on this may lead to unit malfunction and software errors Do not expose unit to heat or fire high temperature impact may lead to case deformation and circuit board da...
Page 4: ...r of users 1 000 000 Number of proximity cards 1 000 000 Number of palms veins patterns 300 000 Identification time by palm veins 1 1000 Less than 2 seconds FAR False Acceptance Rate 0 00008 Interface for communication with computer Ethernet IEEE 802 3 100BASE T Power supply 12VDC 15 1A standalone 3A with readers Power relay outputs NC С NO outputs 2 Power rating of power relays 12 24VDC 7А Number...
Page 5: ...ates if Relay 1 is powered on REL2 LED Indicates if Relay 2 is powered on IN_1 LED Indicates if discrete input 1 is activated IN_2 LED Indicates if discrete input 2 is activated IN_3 LED Indicates if discrete input 3 is activated IN_4 LED Indicates if discrete input 4 is activated IN_5 LED Indicates if discrete input 5 is activated IN_6 LED Indicates if discrete input 6 is activated RST Jumper Res...
Page 6: ...s door sensors 21 IN3 Discrete input 3 Enter exit buttons door sensors 22 WO10 Wiegand output 1 DATA0 External controller Wiegand 1 23 GND Wiegand ground External controller Wiegand ground 24 WO11 Wiegand output 1 DATA1 External controller Wiegand 1 25 IN4 Discrete input 4 Enter exit buttons door sensors 26 IN5 Discrete input 5 Enter exit buttons door sensors 27 IN6 Discrete input 6 Enter exit but...
Page 7: ...an category five with a wire size of no less than 0 2 mm2 General installation notes Install the controller on vertical surface Cables must be installed in accordance with the operational code for electrical installations Do not lay cables within 30 cm of sources of electromagnetic interference All cables must only intersect power cables at a right angle All cable extensions must be soldered Caref...
Page 8: ...Press the controller to the DIN rail the upper clip must snap under the pressure of the spring Power supply connection Use a DC 12 V power supply adaptor with a minimum of 1000 mA 3000 mA if PV WM readers are to be connected via Ethernet which has obtained the approval of IEC EN 60950 1 See recommended cable type and maximum length of the cable in Cable types table ...
Page 9: ...ion Guide v1 2 10 2018 en Network connection See recommended cable type in Cable types table The order of connections in the cable s modular connector must correspond to the TIA EIA 568 B standard PV WM Readers connection ...
Page 10: ...ders to 12V power supply if UniPass on board PoE ports are used Fail safe lock connection See recommended cable type in Cable types table Install a diode as it shown on figure to protect controller relay from reverse current Use 1N4007 diode 1000V 1A or similar Use separate power supplies for lock and controller ...
Page 11: ...il secure lock connection See recommended cable type in Cable types table Install a diode as it shown on figure to protect controller relay from reverse current Use 1N4007 diode 1000V 1A or similar Use separate power supplies for lock and controller ...
Page 12: ...11 UniPass Installation Guide v1 2 10 2018 en Exit buttons and door sensors connection See recommended cable type in Cable types table Wiegand connection See recommended cable type in Cable types table ...
Page 13: ...Support support biosmart tech com 420 246 097 126 Skype BioSmart TechSupport 420 246 097 126 Konevova 2660 141 130 00 Prague Czech Republic www biosmart tech com sale biosmart tech com ...