Operation Manual BioSmart PV-WM v.029.1|03.2021|en
Page 15 of 24
BioSmart PV-WM Reader
Operation Manual
Figure 8
–
Sealed lead-in composition
Sequence of step:
screw the connecting branch of sealed lead-in from the side of the tooth-type coupling,
leaving a hole large enough to insert the cable to be fixed;
install a rubber seal ring on the connecting branch of sealed lead-in;
insert the connecting branch of sealed lead-in into the cable hole on the back cover of the
reader so that the rubber seal ring is tightly clamped between the outer side of the back cover
and the wide part of the nipple;
screw the fastening nut onto the connecting branch thread protruding from the back (inner)
side of the reader back cover.
b)
with the sealed lead-in installed, connect the reader to the Ethernet network, for which do the
following:
insert the uncrimped end of the cable into the sealed lead-in and stretch the cable to the
required length, if
it’s necessary
first loosen the hold-down nut;
“crimp” the end
of the cable in accordance with Figure 9;
tightly tighten the hold-down nut from the outside of the back cover;
insert the connector into the Ethernet port.
Hold-down
nut
Sealing disk
Connecting
branch
Rubber seal ring
Anchor nut