70
-
4.2 LCD Display under Normal Operation
When all hard disks work normal, LCD will display normal status as below.
RAID-0
NORMAL
RAID-10
NORMAL
RAID-6
NORMAL
RAID-3
NORMAL
RAID-5
NORMAL
4.3 LCD Display for Disk Error
RAID-x
ONE DRIVE DOWN
This means host access is working under one failed drive status.
(
This
won’t be seen on RAID-0 mode
)
Please check disk FAIL LED to identify the failed drive. Press MODE button to stop buzzer alarm.
RAID-x
TWO DRIVE DOWN
This means host access is still working under 2 failed drives status.
(
This will only be seen in RAID-6 mode
)
Please check disk FAIL LED to identify the failed drive. Press
MODE button to stop buzzer alarm.
SYSTEM
DOWN
This will be shown if 3 drives failed in RAID-6 mode or 2 drives failed in RAID-3/5 mode, or one drive failed in
RAID-0 mode. The controller will do its best to handle host command, but normal operation is not guaranteed.
Please check disk FAIL LED to identify the failed drive. Press MODE button to stop buzzer alarm.