5 THERMOSTAT AND GSM MODULE HOOKUP
The Controller has a capability to hook up one room thermostat and one safety
thermostat with contact type NO. In addition, there is a capability to hook up GSM
module for remote control of the burner operation. The hookup diagram is shown on
Picture 22.
Picture 22 – Hookup Diagram for Sensors, Room Thermostat, Safety Thermostat and
GSM Moduel
6 APPLICATION INSTRUCTIONS
6.1 Operating Restrictions
MPT-AIR BIO PID Controller for solid fuel boilers has the following operating
restrictions:
Parameter Description
MPT-AIR BIO PID
Permissible humidity, %
from 40 to 90, non-
condensing
Permissible atmospheric pressure, kPa
from 84 to 107
Case proofness per GOST 14254
IP 41
Temperature sensor hardness, °C
from -55 to +125
Operating temperature range, °C
from 10 to 50°C
6.2 Installation Rules
While installation and operation it is recommended to adhere to the following
rules:
the Controller shall be used for its intended purpose only;