F.
CHANGING UV LAMP AND QUARTZ SLEEVE
When a lamp is defective, we recommend to change all lamps and to keep those still valid for the next
repairs.
1
SWITCH OFF the reactor CUT the POWER source and EMPTY IT.
2
Unscrew and remove the cover.
3
Unplug each connector of lamp and the ground plug if necessary.
4
Remove the support from the cover.
5
Make sure that the UV lamp is cooled before handle it.
6
Take out the UV lamp (if necessary use the connector) and place it on a clean
and soft surface.
Carry out this operation CAREFULLY
taking care not to place your
fingers outside the cap.
7
Undo the stainless steel nut
Remove the flat washer.
8
Gently remove the quartz sleeve:
Insert a thumb or finger in the sleeve and withdraw it until the seal comes
free from its housing.
9
Take hold of the quartz sleeve and extract it fully making sure that you keep
it correctly aligned with the axis.