background image

Therapeutic Infrared Heat

 

.

 

  .

I

 

O

 S 

M

 

A

 

R

 

T

®

Save these 
Instructions

Includes:

  Application Guidelines

  User Information & Guidelines

  Operating Instructions

  Warranty & Servicing

In-Wall Heater

 

Owner’s Manual

Therapeutic infrared heating systems

for a green, healthy environment

with Patented BioSmart

®

 

Air Filtration Technology

BioSmart

®

 In-Wall Far Infrared Heaters. 

Feel the Difference.

BioSmart 

Technologies

Summary of Contents for BioSmart 1000F

Page 1: ...ser Information Guidelines Operating Instructions Warranty Servicing In Wall Heater Owner s Manual Therapeutic infrared heating systems for a green healthy environment with Patented BioSmart Air Filtr...

Page 2: ...Customer Warranty Service 800 595 9605 BioSmart BIO 1000F In Wall Edition Far Infrared Heater...

Page 3: ...How many units do I need 10 Installation Instructions 10 Wiring Diagrams 13 BIO 1000F 120v Wiring Schematic 13 BIO 500F 120v Wiring Schematic 13 For Your Safety Warning 14 For Best Performance 14 Oper...

Page 4: ...heat That means drastic reductions in your heating bills up to 50 depending on the type of heating system you have currently installed TheBioSmart isagiantofunparalleledefficiency Thefarinfraredheati...

Page 5: ...se as an integral part of many medical therapies is well documented Now you can enjoy the benefits of therapeutic far infrared heat with the BioSmart Ceramic Far Infrared Heater Please read the operat...

Page 6: ...ion and a potential health problem especially for those with respiratory sensitivities and allergies including asthma Energy Saving Benefits It requires less energy to heat the room with far infrared...

Page 7: ...e BioSmart heating system are designed to last longer than other wall heaters BioSmart warranty coverage and service procedures are simple to follow and the heaters can be serviced in ten minutes or l...

Page 8: ...Difference in time required to reach given temperature 47 48 47 67 70 73 76 80 74 83 75 BioSmart Far Infrared vs Standard Coil Type Radiant Heater Nearly 20 faster to 72 F The BioSmart heater reached...

Page 9: ...box edges fold back box flaps Gently turn entire box upside down lift box from protective packaging 3 REMOVE the protective packaging materials from the inside of the heater s heat exchanger making s...

Page 10: ...Page 8 Customer Warranty Service 800 595 9605 BioSmart 500F Features Functions Heat Register Cabinet cover Intake...

Page 11: ...Page 9 2013 BioSmart Technologies BioSmart 1000F Features Functions Heat Register Intake Cabinet cover...

Page 12: ...wall unit as a primary heating source New construction coldest day above 5 degrees standard insulation one window per room Room size up to 500 sq feet 1 unit Room size above 500 to 1000 sq feet 2 unit...

Page 13: ...Page 11 2013 BioSmart Technologies 12 12 Installation Range Backets for BIO 1000F new installation Backets for BIO 500F retrofit installation...

Page 14: ...w and white wires go directly to the thermostat No external power supply is needed Any attempt to attach an external power supply will cause damage to the internal components and will result in produc...

Page 15: ...ies Wiring Diagrams BIO 1000F 120v Wiring Schematic Switch must have a contact separation in all poles that provide full disconnection with a contact separation of at least 3 mm and rated 10A minimum...

Page 16: ...frared heating elements turn on After the heating elements have come up to full temperature a third fan will turn on to increase the airflow into the room This third fan will remain running even after...

Page 17: ...ns on you have a defective thermostat otherwise you have a defective relay in the heater Call a service technician for installation of a new relay Heater doesn t seem to be getting hot enough Most lik...

Page 18: ...wall and the heater The heater cabinet remains cool to the touch while delivering warm 105 C far infrared heat into the room Thermostat Type Any standard digital programmable or mechanical no in line...

Page 19: ...the wall and the heater The heater cabinet remains cool to the touch while delivering warm 105 C far infrared heat into the room Thermostat Type Any standard digital programmable or mechanical no in l...

Page 20: ...t 1000F In Wall Heater A Cover B Case C Heater Core D Grill E Fan Holder F Fans G Insulator Cover H High Limit Reset I Top Case Bracket J Bottom Case Bracket K Ceramic Heating Element L PCBoard M Baff...

Page 21: ...an G Bottom Cover H Bottom Air Guide I PC Board J Electrical Components Divider K Connection Plate L Solid State Relay M Mounting Bracket N Inside Insulator Cover O Insulator P Outside Insulator Cover...

Page 22: ...maintain product in good working order Limitations on labor During the first year of the warranty BT will reimburse the customer 30 for in home contractor service or 100 of labor cost provided that th...

Page 23: ...transportation or storage or failure to follow instructions The Company will not be responsible for any statements that are made or published written or oral that are inconsistent with this written wa...

Page 24: ...SmartTechnologies 18324 Cook Road Suite 1 Yelm Washington 98597 Customer Warranty Service 800 595 9605 North American Distribution and Sales BioSmart Far Infrared Heaters Green Technology for a Modern...

Reviews: