Bio Green BF 2000 Installation And Operating Instructions Manual Download Page 5

12 

Installation and operating instructions for catalytic heater type BF 2000 and BF 3500 

Why does the pilot flame or the main burner go out after an extended period? 

If  your    greenhouse  is  well  sealed,  the  minimum  air  volume  exchange  may  not  be  achieved,  the 

maximum  permissible  CO

2

  concentration  is  thus  exceeded  and  the  device  switches  off 

automatically. 
Over-concentration of CO

2

 can be avoided as described below: 

a) Place the device on an approx. 30-40 cm high pedestal to prevent the CO

2

, which sinks to the

floor, from extinguishing the flame.

b)  Make  an  opening  for  ventilation  near  the  gas  heater  to  provide  the  pilot  flame  with  sufficient

oxygen.

Why is the gas consumption too high? 

The following energy-saving suggestions are good to know: 
a) Please inform yourself about the minimum temperatures your plants require in winter. Do not set

the  thermostat  higher  than  necessary.  Each  additional  degree  means  unnecessary  gas

consumption.  If  the  external  skin  of  your  greenhouse  is  made  of  normal  glass,  heating  is

expensive  due  to  the  high  thermal  conductivity.  A  glass  house  should  be  insulated  with  air

cushion foil. As a rule, this reduces energy costs by up to 30 %.

b)  Energy costs can be further reduced by turning off the pilot flame during the day.

Why is the device leaking? 

The  greenhouse  heater  type  BF  2000  /  BF  3500  is  a  safe  device,  tested  and  certified  by  the 

European CE directives as well as DIN DVGW standards. But our 30-year’s and more of experience 

with gas devices shows that customers make the same handling faults time and again. With cylinder 

exchange, the cylinder – pressure regulator gas tightness is often not checked by the operator. Gas 

leakage  should  be  checked  for  with  leakage  detection  spray  or  soap  water  after  every  cylinder 

exchange. The slightest bubble formation indicates a leaky connection. 

8. Tips on reliable operation

a) When storing the device in summer, it should be stored in a bag, carton or something similar to

protect  it  from  spiders  and  insects.  These  small  creatures  are  attracted  by  the  aromatic

substances in the gas and often block the paths of the gas through dirt they bring in. The heater

subsequently stops working and must be cleaned at a cost by a specialised gas company.

b) If  the  gas  heater  is  operated  with  the  included  pressure  regulator,  ensure  that  the  regulator  is

mounted  at  an  angle  to  enable  possible  condensate  originating  at  the  small  ventilation  hole  on

the side of the pressure regulator dome (head) to run off. Condensate remaining in the pressure

regulator will cause the flame to gradually weaken and eventually extinguish.

9. Cleaning, repairs and disposal

Do not use abrasive, caustic or cleaning agents.

Before cleaning, switch off the device and allow it to cool down for about 30 min. before starting

to clean.

Never submerge the device in water.

Take the devices to be disposed of to an appropriate waste disposal point.

The device may only be repaired by authorised specialists. Please contact the manufacturer or

distributor in this regard.

Attention!

  The guarantee is null and void in the case of incorrect repairs.

Faulty repairs pose a danger to the user and other persons.