Bio Green BF 2000 Installation And Operating Instructions Manual Download Page 2

Installation and operating instructions for catalytic heater type BF 2000 and BF 3500

 

1. Technical specifications

Device type:   

BF 2000 

BF 3500 

Category: 

Cat. I 3+ 

Cat. I 3+ 

Gas type: 

G 30 

G 30 

Supply pressure: 

28-30/37 mbar

28-30/37 mbar

Heating output: 

2000 Watt

3500 Watt

Gas consumption: 

approx. 156 g/h

approx. 297 g/h

Dimensions (l/w/h): 

450/490/160 mm

430/770/170 mm

IMPORTANT: 

Familiarise yourself with the instructions in these operating instructions and the general safety and 

hazard notes before installation. Keep this document in a safe place for future reference. If you have 

any doubts about the safety of the device, please consult a specialist. 

2. General

After unpacking and before starting up, ensure that the device and all the accessories are complete 

and  in  good  order.  In  case  of  transport  damage,  please  contact  the  relevant  distributor  or  the 

manufacturer immediately. Keep packaging material (polybag, polystyrene, nails etc.) out of reach of 

children since such materials may be hazardous. This also applies to small included items that can 

be swallowed. 

3. Safety and hazard notes

If  you  are  unsure  about  functionality,  safety  or  connection  of  the  device,  please  consult  a
specialist.

Disconnect the device from the gas supply if it will not be in use for an extended period.

The device is not suited for use in areas used for animal husbandry.

These  operating  instructions  are  part  of  the  device  and  should  be  kept  in  a  safe  place.  If  the
device is passed on to third parties it must be together with the operating instructions.

In industrial facilities, the accident prevention regulations for electrical installations and operating
material of the industrial employer’s liability insurance association are to be observed.

Should you be unsure about proper connection or should any questions arise that are not dealt
with in the operating instructions, please contact the manufacturer or a specialist.

The  device  must  be  disconnected  from  the  gas  cylinder  when  opening  the  cover  or  removing
components.

Never store or use flammable materials or spray near the device. 

Fire hazard!

Do not use the device in a flammable atmosphere (e.g. close to combustion gas or spray cans).

Explosion and fire hazard!

Do not cover the heater. 

Fire hazard!

Never dry flammable objects in front of the apertures. 

Fire hazard!

The enclosure heats up during operation. Install the device in a manner that prevents accidental
contact. 

Danger of burning!

 After being switched off, the device cools down gradually.

This device may not be operated by persons (including children) with limited physical, sensory or
mental  faculties,  nor  by  persons  who  are  not  sufficiently  experienced  or  adequately
knowledgeable in the use of the product unless such persons are supervised or instructed in the
use of the device by a person responsible for their safety.

EN 