42
WOOD WORKING
This time, when the stove is in wood mode, it is only possible to watch on display the overheating alarm reached inside the pellet tank
whenever the user has the stove connected to the electrical network and it has been ignited from the display. Otherwise, the safety device will
not show the alarm signal.
However, during the wood working, we can see the next working problems of the stove, whose possible reasons and possible solutions are
described on the next table:
PROBLEM
POSSIBLE REASON
SOLUTION
The stove gives
off smoke
Inappropriate use of the stove
Open the primary air intake a few minutes and then open
the door
Smoke duct is cold
Pre-heat the stove
Smoke duct is obstructed
Check the duct and the connector to see if it is blocked or
has an excessive soot
PROFES
Smoke duct is oversized
Install an appropriate diameter
PROFES
Smoke duct is tight
Install an appropriate diameter
PROFES
The draught is not enough
Add length to the chimney
PROFES
Pellet / Wood automatic system blocked
Unblock the system
PROFES
Smoke duct with infiltrations
Seal connections between sections
PROFES
More than one equipment connected to the
duct
Disconnect the rest of equipments and seal the entrances
PROFES
Air returns
Inappropriate use of the stove
Open completely the primary air intake and, later, the door
during a few minutes
Combustion range too low. Lack of draw
Use the stove with an appropriate range. Increase the
primary air intake
Excessive ash accumulation
Empty the ash pan frequently
The smoke duct does not protrude the top
of the roof
Add length to the chimney
PROFES
Combustion out
of control
The door is not sealed properly or is open
Close the door or change the sealing cords
PROFES
Excessive draw
Check the installation or install a draft-diverter valve
PROFES
Refractory sealing plaster is damaged
Check the joints and use refractory putty
PROFES
Smoke duct is oversized
Install an appropriate diameter
PROFES
Strong winds
Install an appropriate chimney cowl
PROFES
Green or wet wood with bad quality
Use dry wood. Air dried during at least 1 year
Insufficient heat Green or wet wood with bad quality
Use dry wood. Air dried during at least 2 years
Lack of primary air
Increase the primary air intake
Smoke duct with air infiltrations
Use an insulated system of chimney
Masonry exterior of the chimney is cold
Insulate thermally the chimney
PROFES
Heat loss in the house
Seal windows, openings, etc
** The note PROFES means that the task must be done by a professional.