hostname
Assign a name to a device
ignition-off-powerdown-timer
Configure the time to router power down after car
ignition off
inactivity-timer
Configure the maximum inactivity time
login
Configure login options
password
Configure the device access password
pool
Number of bytes assigned to each memory pool
schedule-restart
Allows to configure router reset schedule
telnet
Access the TELNET protocol configuration
web-probe
Access the Web probe configuration
Config>set ignition-off-powerdown-timer ?
<1..1440>
Power down timeout in minutes
disabled
Disable ignition off power down timer
Config>set ignition-off-powerdown-timer 10
Config>
For further information on this command, please see the following manual: bintec Dm704-I Configuration and Monit-
oring.
Note
The Power Management feature is always enabled.
In order to disable the Power Management feature, connect the IGNITION signal to the VCC / BAT-
TERY (+). For further information see
Connecting the power cable to the vehicle
on page 9 and
on page 10
3.4 RESET Button
The following sections describe the RESET button features.
Fig. 10:
Reset button
3.4.1 Restarting the device
Once the device is operating normally, you can restart it.
To trigger a restart, follow these steps:
• Press, and quickly release, the hidden RST button using a pin or a needle.
When the device restarts, the WLAN LED flashes once green.
• The device will restart switching on the LVL, Cell and SIM LEDs and after a while will switch them off again.
3.4.2 Default configuration
The RST button allows you to reboot your router with its default configuration. Follow these steps:
bintec elmeg GmbH
3 Components and power supply
bintec H2 Auto Compact
11