13. Notification and alarm functions
13.1 Notification and alarm system overview (auto diagnosis system)
•
Visual indications of notification or error messages are blue notes on the display of the MB1controller.
•
Visual indications of an alarm messages are red notes with an alarm bell symbol.
In addition, there is an audible alert, if you did not deactivate the buzzer in the “User level” menu
(chap. 6.4).
Event
Note
(blue field)
Alarm
(red field)
Lack of water in the freshwater can. The
chamber continues working for a few hours.
In case of freshwater supply via water pipe,
the water tap is closed, or the chamber is
defective.
WATER LOW
after 5 min
Wastewater hose clogged. Check the length
and location of the wastewater hose.
or
Wastewater pump or float switch in the
wastewater can defective. Contact BINDER
service.
WASTEWATER
after 10 sec.
Humidifying module defective. Contact
BINDER service.
FAULT HUMID SYSTEM
immediately
Freshwater can is too empty to allow normal
function, or the chamber is defective.
The humidification system turns off.
Fill up the water can or open the water supply.
During the one-hour preheating phase: mes-
sage without significance
WATER TANK EMPTY
after 60 sec.
When manually filling up the freshwater can:
Freshwater can is too full, or the chamber is
defective. Suck off the water (chap. 4.2.2).
The chamber functions as usual.
If the message persists, contact BINDER ser-
vice.
WATER LEVEL TOO
HIGH
after 60 sec.
Humidity switch OFF or humidity outside con-
trol range. No active humidification of the inte-
rior. Further dehumidification possible by re-
frigerating operation
HUMID OFF
immediately
Maintenance of the humidity module is re-
quired. Contact BINDER service.
HUMID SERVICE
immediately
One-hour preheating phase, no refrigerating
and dehumidification functions
1H PREHEAT PHASE
immediately
Fault in refrigerating machine. Contact
BINDER service.
FAULT COMPRESSOR
immediately
Summary of Contents for MKF 115
Page 97: ...MKF MKFT E3 2 07 2017 page 97 115 20 10 Dimensions MKF 115 MKFT 115...
Page 98: ...MKF MKFT E3 2 07 2017 page 98 115 20 11 Dimensions MKF 240...
Page 99: ...MKF MKFT E3 2 07 2017 page 99 115 20 12 Dimensions MKFT 240...
Page 100: ...MKF MKFT E3 2 07 2017 page 100 115 20 13 Dimensions MKF 720 MKFT 720...
Page 102: ...MKF MKFT E3 2 07 2017 page 102 115...
Page 103: ...MKF MKFT E3 2 07 2017 page 103 115...
Page 104: ...MKF MKFT E3 2 07 2017 page 104 115 21 2 EU Declaration of Conformity for MKFT...
Page 105: ...MKF MKFT E3 2 07 2017 page 105 115...
Page 106: ...MKF MKFT E3 2 07 2017 page 106 115...
Page 108: ...MKF MKFT E3 2 07 2017 page 108 115...
Page 109: ...MKF MKFT E3 2 07 2017 page 109 115 22 Product registration...