Repair work at the outer door
6.1.2
Aligning the adjustable door holder lug with pulley
1. Disconnect the unit from the power supply.
2. Remove the outer door gasket (chap. 6.2.6).
3. By turning the adjusting screw (A) you can change the horizontal position of the door holder
lug (B).
left-hand rotation = inwards
right-hand rotation = outwards
4. Align the door holder lug (B) in a way that the closing of the door (chap. 6.4) can seal easy-
running in the openings of the door holder lug and the door closes tightly all around.
Absolutely avoid screwing in the door holder lug unnecessarily far (left-hand rotation),
because this would cause the adjusting screw to work loose from the thread of the door
holder lug, and the internal spring may fall into the housing. It is not possible to easily
mount or replace the door holder lug or parts of it.
5. Mount the outer door gasket (chap. 6.2.6) and check if the door it is well aligned and closes
tightly (chap. 6.1.1).
B
A
Figure 7: Aligning the adjustable door holder lug with pulley
A
Adjusting screw
B
Door holder lug with pulley
42
Service Manual KBF (E5.2) 04-2015