15
ATTENTION!
It is extremely important that products used in cleaning ensure maximum cleanliness and are
non-toxic.
5.2 Maintenance and Procedures in Case of Breakdowns
The operator must be instructed to perform routine inspections, making minor adjustments,
cleaning and observing signs of breaches that may occur. Examples include: check for extraneous
noises indicating gas leaks; burners that do not light; failure by the equipment to perform the service for
which it is proposed; among others. Actions like these are indispensable to ensure a longer equipment
life.
ATTENTION!
When maintenance is carried out (even with minor adjustments), always check that the
equipment has the burner turned off, the gas pressure regulator (register) closed and the frying
bowl at room temperature;
It is also recommended to always carry out preventive maintenance, checking and adjusting
clearances, cleaning the internal parts, etc. When detecting broken or poorly functioning parts, replace
them, always using original parts.
By performing preventive maintenance, you eliminate the inconvenience of getting the
equipment stopped when you need it most, reducing the cost of maintenance and reducing the risk of
accidents.
Follow the equipment maintenance and adjustment recommendations:
• Change the gas pressure regulator (register) every 5 years or when it is defective;
• Check the expiration date of the gas hose and follow other instructions as recommended by the
manufacturer;
• After finishing the frying process, keep the gas pressure regulator (register) closed, avoiding pressure
in the hose;
• The gas outlet holes on the burner must always be unobstructed. If they become clogged, use a
needle for cleaning on stove;
• The ideal flame should be blue. Each burner tube has a flame regulator, follow the adjustment
instructions in item 4.3 (operating procedures - page 12);
ATTENTION!
Preventive maintenance requires a trained professional.
Whenever any item regarding the safety of the equipment (such as cleaning or maintenance) is
removed, reset it and confirm that it is performing its function correctly.
When you experience any malfunction or non-compliance, refer your equipment to the nearest
service center. See technical assistance on our website:
Summary of Contents for METVISA FG3D
Page 1: ...1 ...
Page 18: ...18 7 ANNEXES Exploded View Drawing ...