75
ADVANCED USE MANUAL DD700
3.6.21 Setup Menu/Customisation/Keys
Insertion
Editor
It is possible to set two series of messages, each one composed of 3 lines of 25
characters, each which can be entered at the top or bottom of any printout.
You will need to do the following:
select the set of messages that you wish to set:
In the header
or
In the
footer
;
enter
Text 1
using the alphanumerical keyboard, as explained in the Using the
terminal chapter in the user manual.
press
to confirm;
repeat the same procedure to set
Text 2
and
Text 3
;
press
ESC
until you return to normal weight display mode.
Resetting
It is possible to reset any entered text. The Resetting item is only provided in the
menu if any text has been included.
3.6.22 Setup Menu/Customisation/Archives
Memory status
It is possible to check whether the terminal memory is occupied, and recover it if
necessary. The memory recovery operation can require a few minutes. We
advise against switching the terminal off during this operation to avoid losing
stored data.
Archives
Status
Product code, Preset Tares, Product Code Total, Generic Code Total (*)(**),
Range Code (**), Range Code Total (**), Client Total (***)(*), RCP Total
(*)(***), and Plate Total (*)(***).
Archive number and function can depend on the type of selected operation. Each
of these archives can be customised to optimise how much memory they occupy
based on terminal application type. The customisation procedure is used to vary
the size of each single archive, defining the number of elements that it can
contain. To access customisation, place the cursor on the designated archive and
press
SELECT
.
By selecting
Create
it is possible to create an archive, by selecting
Delete
it is
possible to delete an archive, or change its size by choosing
Re-size
.
To increase archive size choose
Increase
then follow the instructions provided by
the terminal. To decrease it, on the other hand, choose
Decrease
.
It will tell you if it exceeds the maximum admissible size for the terminal. If this
is the case, and you wish to proceed, you will need to reduce the size of the
other archives. The archive size reduction operation must be carried out with
caution, as it could lead to losing data contained in it. If archive reduction is
such that it affects areas of the memory that already contain data, they will need
to be reset in order to change the archive.