76
DD1050
field:
Zero Track (e) (Z_TRAC).
Category: Zero management (ZERO).
> Given in divisions. Establishes the range around zero within which the zero value is "tracked”
so as to eliminate small and slow variations to the weight indication, e.g. due to powder
dropping on to the scale. Use the 0 (zero) value for batching systems. Zero forced on
unloading is automatically disabled when zero track is eliminated by selecting the 0 (zero)
value. This also occurs if a different value from 0 (zero) has been entered for the forced zero
parameter.
Default Value: [0]
•
(0)
•
(0.25)
•
(0.5)
•
(1)
•
(2)
•
(3)
field:
Initial reset (F_ACCE).
Category: Zero management (ZERO).
> When powered, the terminal gives the value of the weight on the scale in relation to the zero
value programmed during calibration.
Default Value: [ZERCAM]
•
Calibrated zero (ZERCAM)
•
Auto Zero (AUTOZ)
field:
Automatic Zero (AZZAUTO).
Category: Zero management (ZERO).
> The terminal runs through autozero when powered. If it is a legal scale, autozero occurs
between -5% and +15% of the full scale value around the calibrated zero. If it is a non-legal
scale, this range varies from -50% to +50%. Tick to activate automatic zero.
Default Value: [false]; Type: Bool
•
true
•
false
9.6 Bilancia.BilanciaRemota.ConfigSchema.xml
Plugin: PluginCbDeviceAccessScale
Schema: ConfigSchema
Component Name:
Remote sc. - (Bilancia.BilanciaRemota)
Category:
- (Scale)
SubPath:
-
field:
Network node (param_Nodo).
> Indicates the network node. The terminal used is indicated with localhost. Select node from
pop-up list.
Default Value: []; Type: String, Length MAX: 20
field:
Name of network node (param_Alias).
> Indicates the mnemonic name of thje network node. The terminal used is indicated with
localhost. Select node from pop-up list.
Default Value: []; Type: String, Length MAX: 20
Summary of Contents for DD1050
Page 1: ......
Page 2: ......
Page 57: ...57 DD1050 8 PROGRAMMING DIALOGUES VIA SERIAL LINKS SEE COMMUNICATIONS MANUAL ...
Page 96: ...96 DD1050 ...