22
DD1050
3.3 12 V dc power supply
Weighing terminal D1050 can also be powered by a direct current source with 12 V voltage
rating.
• The power can be supplied by a lead battery or stabilized power supplier.
• The source must be able to supply 4A.
• An external disconnector must be installed.
I--(Figure9-3.jpg)--I
figure 3.3 - View of the power connector
WARNING
Sizing and routing of the power cable and external knife switch are at the customer's charge.
3.4 CONNECTION Of THE TERMINAL TO THE WEIGHING
PLATfORM
To connect the terminal to the weighing platform, the supply normally includes a pre-wired cable
whose female connector must be fully inserted into the 9/15-pin male terminal (JBIL) at the
botton of the indicator. The connection may be different, depending on the type of transducer
installed on the weighing platform, i.e. analog or digital.
WARNING
The cable screen must always be connected to the metal protection cap of the 9/15-pin
connector.
Do not route the connection cable to the weighing platform together with cables routed to power
drives.
SCHERMO
+12V
END