background image

1

BIJUR DELIMON INTERNATIONAL

(919) 465 4448 

LOCAL   

 

(800) 631 0168 

TOLL-FREE    

(919) 465 0516 

FAX   

 

WWW.BIJURDELIMON.COM/MOBILE

1 Copley Parkway, Suite 104    
Morrisville, NC 27560

35993  •  R6 

04/19

PM3 Pump

55:1, Air-operated, Grease

General

The PM3 Pump is a compressed air-operated reciprocating piston pump designed for high pressure 
greasing. These pumps are compatible with all types of mineral and synthetic greases (up to NLGI 
grade 2 viscosity). These pumps can be supplied as separate components or as complete systems 
with all the elements necessary for installation. These pumps can be mounted on mobile units as well 
as on fixed drums and connected to a distribution line for single reel use.

Operation

This pump is self-priming. To prime it the first time, connect the air supply to the pump and slowly 
increase the air pressure from 0 to the desired pressure using a pressure regulator, while keeping 
the outlet valve opened. Once grease begins to flow through the grease gun/guns, the pump is 
primed. 

(Note: It is important that the foot valve of the pump does not come into contact with 

contaminated surfaces, such as a workshop floor, as it may become contaminated with dirt or 
foreign particles that can damage the seals.)

Technical Data

Maximum Air Pressure

140 psi (10 bar)

Minimum Air Pressure

20 psi (1.5 bar)

Maximum Delivery

0.7 lb/min (21 cu.in./min)

Air Inlet Thread

1/4” NPT (F)

Grease Outlet Thread

1/4” NPT (F) (includes 1/2”-27 male conn)

Air Piston Diameter

2.75” (70mm)

Air Piston Stroke

1.5” (35mm)

Installation

These pumps must be mounted on drums using 
covers fitted with a 2” bung. Loosen the star nut 
(48a) of the bung adapter to remove the lower 
nut (48c) and screw this into the 2” bung 
opening of the cover. Place the star nut (48a) 
and the three jaws (48b) on the suction tube. 
Lower the pump through the opening and fasten 
the assembly at the desired height. Secure the 
cover to the drum with the thumbscrews.

   

 

Always keep fingers and hands away from 
moving parts. Do not dent or damage the 
riser tube.

 

Ensure that the mounting surface and 
attachments are strong enough to 
support the lift and pump assembly 
during operation.

48a

48b

48c

Summary of Contents for PM3

Page 1: ...grease gun guns the pump is primed Note It is important that the foot valve of the pump does not come into contact with contaminated surfaces such as a workshop floor as it may become contaminated with dirt or foreign particles that can damage the seals Technical Data Maximum Air Pressure 140 psi 10 bar Minimum Air Pressure 20 psi 1 5 bar Maximum Delivery 0 7 lb min 21 cu in min Air Inlet Thread 1...

Page 2: ...90 psi 6 bar the recommended pressure An air shut off valve must be installed to be able to close the compressed air line at the end of the day if the air inlet is not closed and there is leakage in some point of the grease outlet circuit the pump will start automatically emptying the container Item Description A Air shut off valve LP B Filter regulator C 2 air hose D Quick coupling E Connection n...

Page 3: ...se valve body 40 2 Clean the check ball 43 and its seat in the high pressure piston 44 If damaged replace all the affected parts 3 If the high pressure piston 44 is scored unscrew the high pressure cylinder 51 from the suction tube 47 and from the foot tube 53 and replace it Assemble the pump following the previous instructions reversing each step Inverting Set and Air Motor 1 Secure the air motor...

Page 4: ...octite 242 or equivalent Grease has by passed to the air motor caused by worn or damaged seals 33 or seal O ring 31 Replace the worn or damaged parts Air is leaking through the outlet muffler The sliding valve 19 does not close correctly Disassemble and clean Replace damaged components The valve strap 20 or the toggle spring 25 are damaged Replace damaged components The air piston 4 is damaged Rep...

Page 5: ...ensional Schematics Part A B C D F300 610mm 24 200mm 7 87 42mm 1 6 410mm 16 1 F302 925mm 36 5 200mm 7 87 42mm 1 6 725mm 28 5 F304 1120mm 44 200mm 7 87 42mm 1 6 920mm 36 2 9035 610mm 24 200mm 7 87 42mm 1 6 410mm 16 1 9120 925mm 36 5 200mm 7 87 42mm 1 6 725mm 28 5 9400 1120mm 44 200mm 7 87 42mm 1 6 920mm 36 2 A D C B Measurements shown in millimeters PM3 Pump 55 1 Air operated Grease ...

Page 6: ...1 Copley Parkway Suite 104 Morrisville NC 27560 35993 R6 04 19 Service Parts Drawing All Models except 9120 9400 1 2 3 2 4 5 7 8 56 57 9 10 11 12 13 15 14 16 17 18 19 20 22 21 25 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 24 23 61 6 54 53 58 50 59 51 60 52 43 44 55 47 46 46 PM3 Pump 55 1 Air operated Grease ...

Page 7: ...5400 57 Muffler Circlip F942728 58 Air piston rod F740225 59 Union nut F740203 60 Grease valve body F740205 61 Toggle nut F740150 Service Parts Kit Listings Item s Includes FGK1 Air piston nut 1 Air piston plate 2 Air piston 3 Air Piston Washer 4 Upper packing nut 5 Small O ring 6 Air Motor Space 7 Large O ring 8 Paper valve gasket 9 Valve seat 10 Valve guide plate 11 Valve slide 12 Valve strap 13...

Page 8: ...ILE 1 Copley Parkway Suite 104 Morrisville NC 27560 35993 R6 04 19 Service Parts Drawing Models 9120 9400 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 52 58 59 51 60 25 25 50 44 50 1 2 3 2 4 5 7 8 56 57 9 10 11 12 13 15 14 16 17 18 19 20 22 21 24 23 61 6 54 53 43 55 47 46 46 PM3 Pump 55 1 Air operated Grease ...

Page 9: ...d F740225 59 Union nut F740203 60 Grease valve body F740205 61 Toggle nut F740150 Service Parts Kit Listings Item s Includes FGK1 Air piston nut 1 Air piston plate 2 Air piston 3 Air Piston Washer 4 Upper packing nut 5 Small O ring 6 Air Motor Space 7 Large O ring 8 Paper valve gasket 9 Valve seat 10 Valve guide plate 11 Valve slide 12 Valve strap 13 Washer 14 3mm Allen screw 15 Trip shoe 16 Toggl...