HAP-P Lubricator
Manual, One Shot
General
Lubricator includes a spring return piston pump and is operated by pushing a lever which raises a
piston and compresses a spring, discharging oil into the system. Discharge volume and pressure are
independent of oil viscosity.
Operation
Lubricator includes a spring return piston pump in a plastic reservoir. Pulling up slowly on the lever
handle to the stop fi lls the cylinder with a predetermined volume of oil. Upon release, spring pressure
discharges the oil into the system and returns the handle to the original position. Lubricator must be
operated at intervals recommended by machine manufacturer.
Technical Data
Reservoir Capacity
475cc (1 pint)
Lubricator Inlet Filter
40 micron particle separation
Discharge Pressure
60 psi average
Factory Discharge Setting
15cc
Piston Diameter
1/18”
Piston Stroke Setting
1/2 to 1-1/8”
Discharge Volume Per Stroke
5 to 15cc
Viscosity range
100 to 10,000 SSU at operating temperature
Outlet
1/8”NPTF
Notes Regarding Use
1. Lubricator inlet fi lter should be inspected periodically and cleaned/replaced as required.
To install replacement, disconnect discharge tubing and remove cylinder cap.
2. Discharge pressure will decrease as discharge volume decreases and the number of meter units
in the system increases.
Piston Stroke Setting
1-1/8”
13/16”
21/32”
1/2”
Discharge Volume/Stroke (cc)
15
10
7.5
5.0
System & Limitations
Use meter units type F. Total system fl ow (ø) limitation is given in the table below.
Meter Units (#)
CC Per Shot
5.0
7.5
10
15
15
1750
2400
2900
3500
20
1500
1700
2200
2600
25
1230
1500
1700
2000
30
950
1200
1400
1700
40
780
960
1100
1300
50
640
820
920
1100
60
570
710
810
960
70
500
600
720
860