background image

 

Page 1 of 12

 

 

BA_2005_1_GB_FWA 

replacement for 21131/32 BA 1e/ 031101HF 

 

Operating Instructions 

Pump FW-A 

 
 
 
 
 
 
 
 
 
 

 

INDEX 

 Page 
 

  1.  General  ................................................................................. 2 

 

  2.  Safety .............................................................................. 2 – 4 

 

  A  Pump type  ............................................................................ 5 

 

  B  Number of outlets  ................................................................ 5 

 

  C  Inspection ............................................................................. 5 

 

  D  Kinds of drive ....................................................................... 5 

 

  E  Position of drive  .................................................................. 5 

 

  F  Reservoir  .............................................................................. 6 

 

  G  Accessories  ......................................................................... 6 

 

  3.  Application  ........................................................................... 7 

 

  4.  Principle of operation .......................................................... 7 

 

  5.  Installation ............................................................................ 8 

 

  6.  Specification  ........................................................................ 8 

 

  7.  Adjustment of output volume ............................................. 8 

 

  8.  Maintenance ......................................................................... 9 

 

  9.  Changing the number of outlets  ...................................... 10 

 10. 

Plates 

.................................................................................. 11 

 11. 

Manufacturer's 

declaration 

............................................... 12 

 

 
 

Summary of Contents for FW-A

Page 1: ...y 2 4 A Pump type 5 B Number of outlets 5 C Inspection 5 D Kinds of drive 5 E Position of drive 5 F Reservoir 6 G Accessories 6 3 Application 7 4 Principle of operation 7 5 Installation 8 6 Specification 8 7 Adjustment of output volume 8 8 Maintenance 9 9 Changing the number of outlets 10 10 Plates 11 11 Manufacturer s declaration 12 ...

Page 2: ...on de 2 Safety These operating instructions contain fundamental instructions which are to be observed during erection operation and maintenance Therefore it is absolutely necessary for the fitter and the competent qualified staff user to read these operating instructions before installation and start up The operating instructions must be available at all times at the place of use of the machine sy...

Page 3: ...rating and safety rules of the user are to be observed 2 5 Safety instructions for the user operator If hot or cold machine parts lead to dangers these parts have to be protected against touch Protection against touch for moving parts e g coupling must not be removed when the machine is in operation Leakages e g from the shaft seal of hazardous goods to be delivered e g explosive toxic hot are to ...

Page 4: ... 4413 8 98 1 DIN EN 983 9 96 ISO 4414 8 98 1 DIN EN 1050 1 97 ISO 14121 2 99 1 DIN EN ISO 1200 1 and 2 4 04 1 DIN EN 60204 1 11 98 IEC 60204 1 5 00 2 DIN EN 60947 5 1 2 05 IEC I 60947 5 1 11 03 2 DIN EN 61000 6 2 8 02 IEC 61000 6 2 1 05 3 DIN EN 61000 6 3 8 02 IEC 61000 6 3 1 05 3 DIN EN 61000 6 4 8 02 IEC 61000 6 4 1 05 3 3 0 Notes on environmental protection and waste disposal In correct operati...

Page 5: ...body 12 outlets 3 suction channels 2 Pump body 24 outlets 1 suction channel 2 Pump body 24 outlets 3 suction channels C INSPECTION Stage A D KINDS OF DRIVE Oscillating lever drive 6 5 1 Oscillating lever drive 34 1 Free end stud 6 5 1 Free end stud 34 1 Flange gear motor 6 5 1 220 380 V 50 Hz 0 55 kw 80 U min Flange gear motor 34 1 220 380 V 50 Hz 0 55 kw 80 U min Flange gear motor 6 5 1 290 500 V...

Page 6: ...As sensor serves an ultrasonic sensor As soon as the min or max level allowed has been obtained a signal is released With the help of a signal lamp at the reservoir this signal can be used for the visual warning or for the control of an automatic filling facility In case of receiving the order we will attach particular operating instructions to the level switch with the following code BA_2005_1_GB...

Page 7: ... 1 at the bottom Two bevel gears 20 and 26 which a transmission ration of 1 1 transmit the rotary motion of the driving bush 24 to the control cylinder 21 which carries the stroke operating cam disc 12 For each rotation of the control cylinder the cam disc 12 fixed to it moves each piston 17 one for each outlet up and down three times suction and delivery stroke At each suction stroke gerase is su...

Page 8: ...channels and the ration The pipes may then be connected to the lubrication points and after setting the required grease pumping rate the system is ready to operate 6 Specification Number of pump bodys 1 2 1 2 Numner of pipe connections 1 to 12 13 to 24 1 to 12 13 to 24 Number of suction channels in the control cylinder 1 3 Number of delivery strokes per piston for each rotation of the stroke opera...

Page 9: ... dirt gets into the reservoir when its cover is opened Foreign matter and dirt are the commonest cause of operational difficulties The resevoir can be filled after removing the cover 6 or it can be filled through the filling valve by means of a separate filling or drum pump A filling valve is supplied to special order Grease should be added until its level is 1 2 cm below the rim of the reservoir ...

Page 10: ...sv in the mouth of the piston and holt it Turn the cam disc until the cam projection is near the piston so that the next piston can be put on and guided into its bore For the other piston in succession in the same way excep for those the associated outlets of which are no longer required Press the cam disc and the pistons down and turn them until the holes for the cylindrical pins in the cam disc ...

Page 11: ...Page 11 of 12 BA_2005_1_GB_FWA replacement for 21131 32 BA 1e 031101HF 10 Plates Name plate 110 x 60 mm 75511 1531 Type plate 110 x 60 mm 75511 1321 ...

Page 12: ...ating data sheet both being valid for the product We Company Address Telephone DELIMON GmbH Arminstraße 15 40227 Düsseldorf 49 211 77 74 0 hereby declare on our sole responsibility that all products supplied by us and being relevant to guidelines and which this declaration refers to conform to the mentioned standards and that they if necessary were released by a competent authority Applied harmoni...