DP5 Pump

5:1, Air-operated, Heavy duty, Oil

General

The dP5 Pump is a compressed air-operated reciprocating piston medium pressure pump. These 
pumps are suitable for distribution of all types of light and heavy viscosity oil through pipe lines, hose 
reels and meters. High output allows simultaneous operation when used with multiple outlet systems. 
These pumps can be supplied as separate components systems with all elements necessary for its 
installation. Pumps may be mounted on drums, tanks or the wall, using the appropriate accessories.

Operation

This pump is self-priming. To prime it the first time, connect the air supply to the pump and slowly 
increase the air pressure from 0 to the desired pressure using a pressure regulator, while keeping 
the outlet valve opened. Once oil begins to flow through the oil gun/guns, the pump is primed. 

(Note: It is important that the foot valve of the pump does not come into contact with contaminated 
surfaces, such as a workshop floor, as it may become contaminated with dirt or foreign particles 
that can damage the seals.)

Technical Data

Maximum Air Pressure

140 psi (10 bar)

Minimum Air Pressure

40 psi (3 bar)

Maximum Delivery

10 GPm (37 liter/min)

Air Inlet Thread

3/8” nPT (F)

Oil Outlet Thread

1” nPT (F)

Air Piston Diameter

~4” (90mm)

Air Piston Stroke

4” (100mm)

Installation

These pumps can be mounted directly on a 
drums, tanks or on a wall bracket fitted with a 
2” bung. Loosen the star nut (33a) of the bung 
adapter to remove the inferior nut (33c) and 
screw this into the 2” bung opening of the drum 
or bracket. Place the star nut (33a) and the 
inside part (33b) on the suction tube. introduce 
the pump through the opening and fasten the 
assembly at the desired height by tightening the 
star nut (33a).

33a

33b

33c

   

 

Always keep fingers and hands away from 
moving parts. Do not dent or damage the 
riser tube.

 

Ensure that the mounting surface and 
attachments are strong enough to 
support the lift and pump assembly 
during operation.

Summary of Contents for DP5

Page 1: ...egins to flow through the oil gun guns the pump is primed Note It is important that the foot valve of the pump does not come into contact with contaminated surfaces such as a workshop floor as it may become contaminated with dirt or foreign particles that can damage the seals Technical Data Maximum Air Pressure 140 psi 10 bar Minimum Air Pressure 40 psi 3 bar Maximum Delivery 10 GPM 37 liter min A...

Page 2: ... 3 and 10 bar 90 psi 6 bar is the recommended pressure An air shut off valve must be installed to be able to close the compressed air line at the end of the day if the air inlet is not closed and there is leakage in some point of the grease outlet circuit the pump will start automatically emptying the container Item Description A Air shut off valve B Filter regulator C Air hose D Quick coupler E A...

Page 3: ...ly Check the upper spring 2 and the spring stop 3 inside the air motor cylinder 1 Replace 2 if damaged Remove the lower circlip 16 and muffler 15 and pull up the air motor assembly 4 until the 3 hole in the pump piston 9 becomes visible in the opening where the muffler was removed Insert a steel rod 8mm in the hole to lock the piston and prevent rotation Use a prepared 17mm wrench to remove the ai...

Page 4: ...lve 23 28 or in the foot valve 31 35 Disassemble and clean Replace damaged components Oil is leaking through the exhaust muffler Oil has by passed to the air motor caused by worn or damaged packing set 17 Replace the packing set Air is leaking through the exhaust muffler The upper circlip 11 is worn or damaged Disassemble and clean Replace damaged components The air motor cylinder 1 is scored Repl...

Page 5: ...ecting rod F735410 31 Body base adapter 5 1 F734605 32 Suction tube 5 1 F734604 33 Bung adapter 5 1 F2031 Air motor kit FAHK 1 Upper spring 2 Spring stop 3 Air motor assembly 4 Lower inner spring 5 Lower outer spring 6 Air piston spacer 7 Lower spring carrier 8 Square cut seal 10 Body base O ring 30 Packing set seals kit FAHK 2 Square cut seal 10 Upper circlip 11 Air piston seal 13 Throat seal ass...

Page 6: ...vice Parts Cont Item Description Part Foot valve kit FFV 51 Foot valve O ring 34 Foot valve check spring 35 Check ball 36 Foot valve body 37 Foot valve roll pin 38 Dimensional Schematics Part A B C D F400 720mm 28 3 440mm 17 3 42mm 1 65 280mm 11 F408 1355mm 53 3 440mm 17 3 42mm 1 65 915mm 36 A B D C AIR IN 3 8 OIL OUT 1 See reference image on page 5 Measurements shown in millimeters ...