DP1 Pump

1:1, Air-operated, Oil

General

The dP1 Pump is a compressed air-operated piston reciprocating medium pressure pump. Suitable 
for high flow transfer of high viscosity lubricants and other fluids. These pumps can be supplied as 
separate components or as complete systems with all the elements necessary for installation. These 
pumps may be mounted on mobile units, drums, tanks or walls, using the appropriate accessories. 

(Note: These pumps are designed and intended for transfer only and do not reliably stall under 
pressure when used as a demand pump. They must be controlled with a valve on the air inlet.)

Operation

This pump is self-priming. To prime it the first time, connect the air supply to the pump and slowly 
increase the air pressure from 0 to the desired pressure using a pressure regulator, while keeping 
the outlet valve opened. Once oil begins to flow through the oil gun(s), the pump is primed.  

(Note: It is important that the foot valve of the pump does not come into contact with contaminated 
surfaces, such as a workshop floor, as it may become contaminated with dirt or foreign particles 
that can damage the seals.)

Technical Data

Maximum Air Pressure

140 psi (10 bar)

Minimum Air Pressure

40 psi (3 bar)

Maximum Delivery

15 GPm (60 l/min)

Air Inlet Thread

1/4” nPT (F)

Oil Outlet Thread

3/4” nPT (F)

Air Piston Diameter

2” (50mm)

Air Piston Stroke

4” (100mm)

Installation

The pump can be mounted directly on a drum or 
on a wall bracket fitted with a 2” bung. Loosen 
the star nut (29a) of the bung adapter to remove 
the lower nut (29c) and screw this into the 2” 
bung opening of the drum or bracket. Place the 
star nut (29a) and the split collar (29b) on the 
suction tube. Lower the pump through the 
opening and fasten the assembly at the desired 
height by tightening the star nut (29a).

   

 

Always keep fingers and hands away from 
moving parts. Do not dent or damage the 
riser tube.

 

Ensure that the mounting surface and 
attachments are strong enough to 
support the lift and pump assembly 
during operation.

29a

29b

29c

Summary of Contents for DP1

Page 1: ...ile keeping the outlet valve opened Once oil begins to flow through the oil gun s the pump is primed Note It is important that the foot valve of the pump does not come into contact with contaminated surfaces such as a workshop floor as it may become contaminated with dirt or foreign particles that can damage the seals Technical Data Maximum Air Pressure 140 psi 10 bar Minimum Air Pressure 40 psi 3...

Page 2: ...een 40 and 140 psi 3 and 10 bar 90 psi 6 bar is the recommended pressure An air shut off valve must be installed to be able to close the compressed air line at the end of the day if the air inlet is not closed and there is leakage in some point of the grease outlet circuit the pump will start automatically emptying the container Item Description A Air shut off valve B Filter Regulator C Air hose D...

Page 3: ...top 3 inside the air motor cylinder 1 Replace 2 if damaged Remove the lower circlip 15 and muffler 16 and pull up the air motor assembly 4 until the 3 hole in air piston 8 is visible in the opening where the muffler was removed Insert a steel rod 8 mm in the hole to lock the piston Use a prepared 17mm wrench to disassemble the air motor assembly 4 see drawing on right 4 Remove the air piston 8 and...

Page 4: ...sassemble and clean Replace damaged components Oil is leaking through the exhaust muffler The lubricator is sending too much oil into the airline Adjust the lubricator Oil has by passed to the air motor caused by worn or damaged packing set 17 Replace the packing set Air is leaking through the exhaust muffler The air piston seal 11 is worn or damaged Disassemble and clean Replace damaged component...

Page 5: ...necting rod 1 1 F735208 21 Upper roll pin F943041 22 Lower roll pin F943042 23 Check spring F835300 24 Check washer 1 1 F735206 26 Valve body 1 1 F735207 27 Washer 1 1 F735408 28 Plunger body nut F941008 29 Bung adapter 1 1 F2029 30 Suction tube 1 1 F735204 31 Foot valve screw F735214 32 Foot valve washer F835303 33 Foot valve O ring F946025 34 Foot valve body stub F735229 35 Foot valve nut F94110...

Page 6: ...entre Blvd Suite 109 Morrisville NC 27560 35992 R0 10 09 6 Dimensional Schematics Part A B C D F214 590mm 23 25 365mm 14 5 52mm 2 215mm 8 5 F216 1060mm 41 7 365mm 14 5 52mm 2 695mm 27 3 F218 1285mm 50 6 365mm 14 5 52mm 2 910mm 35 8 A B D C AIR IN 1 4 OIL OUT 3 4 A D AIR IN 1 4 OIL OUT 3 4 Measurements shown in millimeters ...