Page 18
Mounting instructions
AirMaster EM50
Edition: 03/2015 M 2341 GB
3.3 Assembly / mounting / installation
•
Mounting, electrical connection and initial operation may be executed exclusively
by qualified personnel in accordance with EN 50110-01 and EN 1010-1.
•
The installer is responsible for ensuring that the installation and safety instructions
correspond with current standards and provisions in accordance with EN-ISO
13857 and EN-ISO 12100.
•
All fans must be earthed in accordance with the valid standard EN 50178.
•
The fan may not be used as load-bearing part of the building. Fixing other
equipment to the fan or its parts, depositing heavy objects on the fan or stabilising
heavy objects by means of the fan is prohibited.
•
Protect the wire mesh guard, the shutters and the cone against snow and ice loads.
•
If moving parts of the fan (the impeller) are situated less than 2.7 m high (measured
from the floor to the lowest point of the fan), install a protective wire guard in
accordance with EN-ISO 13857.
•
The water outlets must always be open.
•
Do not anchor the fan in its mounting position using cement or construction foam.
Instead, use the optional mounting set.
3.4 Storage and transportation
•
Only transport and store the fan in its original packaging.
•
Storage temperature: -40 °C to +60 °C
•
Avoid impacts to and unnecessary loads on the packaging and/or the fan.
•
Check the fan for damage in case the packaging is damaged.
Caution!
The fan may vibrate during speed control when mounted/installed
incorrectly. This should be checked before completing the installation.
Caution!
The fan must always be installed and mounted securely before it is put into
operation.