Bibby Sterilin TECHNE Tecal 425S Operator'S Manual Download Page 17

PAGE 15

T E C A L  4 2 5 S    O P E R A T O R ’ S   M A N U A L

TECHNICAL INFORMATION

Brief fault finding notes and lists of replacement parts, accessories and
inserts for the Tecal are given in this section.

NOTE THAT THIS EQUIPMENT SHOULD ONLY BE DISMANTLED BY
PROPERLY TRAINED PERSONNEL. 

REMOVING THE OUTER COVERS

OR BASE EXPOSES POTENTIALLY LETHAL MAINS VOLTAGES.

THERE ARE NO OPERATOR SERVICEABLE PARTS WITHIN THE
EQUIPMENT.

General advice

In the unlikely event that you experience any problems with your Tecal which
cannot be easily remedied, you should contact your supplier and return the
unit if necessary. Please include any details of the fault observed and
remember to return the unit in its original packing. The insert must be
removed from the unit and packed separately within the case. Techne
accept no responsibility for damage to units which are not properly packed
for shipping: if in doubt, contact your supplier.

General fault finding

Over temperature cutout

Your Tecal unit is fitted with two independent circuits to protect it from
overheating. The unit constantly checks that the block temperature does not
exceed its maximum. If for some reason this temperature is exceeded, all
power to the block is cut.

Allow the unit to cool to a safe temperature (less than 100

°

C) before

switching off and check for any obvious causes of overheating before
switching it back on.  Switching off the mains power resets the over-
temperature cutout.

Repeated cutouts indicate a serious fault and you should return the unit to
your supplier for repair.

Cleaning your Tecal unit

Before cleaning your unit, disconnect from the power supply and allow to
cool to ambient temperature.

You can clean the case of the Tecal with a cloth dipped in water or ethanol
(methanol can also be used). No part of the case or cover should be
immersed in the solvents.

Do not use acetone or abrasive cleaners.

Before using any cleaning or decontamination method except those
recommended in this manual, the responsible body should check with
Techne that the proposed method will not damage the equipment.

HELP display

If HELP is displayed there is a problem with the internal sensing device.  The
calibrator should be returned to your supplier for repair.

Summary of Contents for TECHNE Tecal 425S

Page 1: ...Tecal 425S Calibrator Operator s Manual Issue 5 Date of issue 3rd May 2005 Techne is a trademark Techne 2003...

Page 2: ......

Page 3: ...ions 8 Warning 8 Specification 9 Working Conditions 9 Packing 9 WHEN YOU SWITCH ON 10 Front Panel controls 10 Setting the Units for Temperature 12 Setting the Operating Temperature 12 Cooling Probe 13...

Page 4: ...PAGE 2 T E C A L 4 2 5 S O P E R A T O R S M A N U A L...

Page 5: ...PAGE 3 T E C A L 4 2 5 S O P E R A T O R S M A N U A L NOTES...

Page 6: ...that the air inlet vents on the underside are free from obstruction 5 Note that the following symbols may be next to the indicator lamps on the front panel of the units and have the following meanings...

Page 7: ...assurant que les trous d a ration situ s sous l appareil ne sont pas obstru s 5 Les symboles ci dessous situ s c t des t moins lumineux sur la face avant de l appareil ont la signification suivante t...

Page 8: ...Entl ftungsrippen an der Ger teunterseite immer frei zug nglich sind 5 Wenn die Anzeigenl mpchen an der Vorderseite leuchten hat dies folgende Bedeutung Ger t ist eingeschaltet Ger t heizt bertemperat...

Page 9: ...to a las luces indicadoras en el panel frontal del equipo tienen los siguientes significados Indicador de potencia Indicador del calor Indicador de sobretemperatura 6 Los s mbolos que se encuentran en...

Page 10: ...tailed towards the back of this manual Maintaining a set temperature The required temperature is set on the calibrator and the operation of the probe is checked A UKAS certificate can be provided cont...

Page 11: ...of inserts at the back of this book Depth 130mm 5 1 Diameter 38 2mm 1 5 Reference well Depth 101 6mm 4 Diameter 6 6mm 0 26 Working conditions The Tecal units are designed to work safely under the foll...

Page 12: ...econd then the actual temperature of the block will be indicated The Front Panel Controls The front panel controls consist of three buttons for controlling the display a five digit LED display and thr...

Page 13: ...ndicator shows that there is power to the unit Power to the Block Indicator The next indicator shows when there is power to the block When the set temperature is higher than the block temperature this...

Page 14: ...ROW buttons at the same time To convert back press both buttons again Setting the Operating Temperature 1 To display the set temperature on the digital display press and hold the SET Temperature butto...

Page 15: ...ive build up of moisture will occur which may cause damage to the interior of the unit After Use 1 When you have finished heating samples remember that parts of the unit inserts and associated accesso...

Page 16: ...owered up otherwise data integrity cannot be guaranteed Once the cable is fitted it does not matter which unit is powered up first RS232 9 way PC serial port ON OFF switch Fuses Power inlet The follow...

Page 17: ...ndent circuits to protect it from overheating The unit constantly checks that the block temperature does not exceed its maximum If for some reason this temperature is exceeded all power to the block i...

Page 18: ...calibrator to your supplier for repair Never fit a fuse rated higher than the value indicated on the unit serious damage or personal injury may result Replacement parts Each unit is supplied with an...

Page 19: ...ation Aluminium Inserts Immersion depth 114 3 mm or 4 5 NUMBER PROBE DIAMETER METRIC FINSALA 5 off 6mm FINSALB 1 off each 10mm 8mm 6mm 4 5mm 3mm FINSALC 2 off 6mm 2 off 10mm FINSALD 2 off 6mm 2 off 12...

Page 20: ...PAGE 18 T E C A L 4 2 5 S O P E R A T O R S M A N U A L...

Page 21: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...

Reviews: