Biamp Vocia VO-4e Operation Manual Download Page 4

 

 

VO-4e Front 

System Indicators 

The LED indicators on the front panel provide information and operational status of the unit and 
associated output channels. LEDs have been grouped into Chassis and Channel indicators.  

Chassis Indicators  

These indicators relate to the entire unit (chassis).  

PoE 

PoE is a green LED indicator that will illuminate when PoE power is applied to the unit via either or both 
CobraNet ports.  

Aux 

Aux is a green LED indicator that will illuminate when an auxiliary DC supply is applied to the unit via 
either or both 24V Auxiliary power inputs.  

Chassis Fault 

Chassis Fault is a amber LED indicator that illuminates when a Chassis Fault has occurred. There are 
two types of Chassis Faults that can be reported depending on the severity of the problem. Flashing 
amber indicates a Warning that means some aspect of the unit is not performing within normal 
specification. Audio may still be passing but if the condition causing the warning is not corrected chassis 
failure may occur. Solid amber indicates a fault which means that some aspect of the unit has failed and 
audio may no longer be passing through the device. Use Vocia software to determine the specific type of 
chassis warning or Fault that has occurred.  

Activity 

Activity is a two-color LED that indicates the configuration status of the device. A solid green LED 
indicates that the unit is configured. A flashing yellow LED indicates the unit is active but unconfigured. A 
solid yellow LED indicates the unit is configured and in standby. Standby only occurs when a unit has 
been designated as a redundant device when Device Failover is enabled.  

Status 

Status is a tri-color LED that indicates the health of the hardware. A green LED indicates that the unit 
powered up normally. A flashing amber LED is shown briefly during the power-up self-test and will turn 
solid green upon successful start. A red LED indicates that the unit experienced a problem during the 
power-up self-test.  

Channel Indicators  

These indicators relate to each of the four channels.  

Amp Fault

 is a amber LED that illuminates when the corresponding Amp Fault Input on the rear of the 

unit has been asserted.  

Activity

 is a two-color LED that illuminates green when that channel is configured and actively passing 

audio and yellow when that channel is configured and in standby. Standby only occurs when a channel 
has been designated as redundant channel in a failover configuration.  

Signal

 is a tri-color LED that illuminates in the following manner when audio signal is present. Detailed 

metering of current output levels can be obtained in real time via the Vocia software interface. 

Red 

Amber 

Green 

Dark 

Signal above clip 
threshold 
> -2dBFS 

Signal above nominal but 
below clip threshold 
> -18dBFS 
< -3dBFS 

Signal above minimum but 
below nominal threshold 
> -48dBFS 
< -19dBFS 

Signal below 
minimum threshold 
< -48dBFS 

  

Summary of Contents for Vocia VO-4e

Page 1: ...VO 4e OPERATION MANUAL 585 0358 90C JANUARY 2016...

Page 2: ...lume control ducking equalization compressor limiter speaker crossover delay and output gain Emergency messages for life safety systems are stored in non volatile memory Two RJ45 connectors on the rea...

Page 3: ...plied by this manual relates to physical connections and assignment For more details on software setup please consult the Vocia Help File Installation The unit requires one 1 75 inch 44 45 mm high and...

Page 4: ...A solid green LED indicates that the unit is configured A flashing yellow LED indicates the unit is active but unconfigured A solid yellow LED indicates the unit is configured and in standby Standby...

Page 5: ...ctory Default Device ID is 01 A Device ID of 00 is invalid and cannot be used To assign a Device ID of hex 07 leave the MSB switch on 0 and turn the LSB switch to 7 Device ID switches should be set us...

Page 6: ...separate Control Inputs are provided via a six way 0 2 5 08mm pluggable screw terminal block Each Control Input allows for an external voltage free contact closure to ground to assert a Control Input...

Page 7: ...e of shielded speaker cable is not supported Highly capacitive speaker lines or loads may prevent correct operation of the ELD detection system Legacy monitored speaker circuits that use capacitors an...

Page 8: ...r by performing a Device Reset in the Vocia software via the Test tab of the device dialog The units are required to be reset within 10 seconds of each other in order to ensure the primary device resu...

Page 9: ...d Impedance 2k Maximum Output Level 22dBu Nominal Output Level 10dBu 0dBu or 4dBu Environment Ambient Operating Temperature 32 113 F 0 42 C Humidity 0 95 Altitude 0 10000 Feet MSL 0 3000 Meters MSL Co...

Page 10: ...Notes Page...

Page 11: ...Notes Page...

Page 12: ...Notes Page...

Page 13: ...t comply with all local codes National Electrical Code ANSI NFPA 70 for United States Canadian Electrical Code Part 1 CSA C22 1 Sections 2 128 12 010 3 and 12 100 for Canada Wall Mounting Instructions...

Page 14: ...ente o si se ha ca do ADVERTENCIA Para reducir el riesgo de incendio o descarga el ctrica no exponga estos productos a la lluvia o humedad Estos productos no deben exponerse a goteos o salpicaduras ni...

Page 15: ...position du produit l humidit ou la pluie fonctionnement anormal du produit chute du produit etc AVERTISSEMENT Pour limiter les risques d incendie ou d lectrocution n exposez pas ce produit l humidit...

Page 16: ...Umgebung gestanden ist sich nicht erwartungsgem verh lt oder wenn es gefallen ist ACHTUNG Um das Risiko eines Brandes oder eines elektrischen Schlages zu vermeiden das Ger t vor Regen und Feuchtigkeit...

Page 17: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 POTS 26 AWG Biamp Biamp ANSI NFPA 70 1 CSA C22 1 2 128 12 010 3 12 100 4 2...

Page 18: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 V Hazardous Live MAINS MAINS MAINS MAINS POTS 26 AWG Biamp Biamp AC MAINS ANSI NFPA 70 Part 1 CSA C22 1 Sections 2 128 12 010 3 12 100 4 2 2...

Page 19: ...Fuses 1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 12 100 12 010 2 128 1 4 POTS AWG 26 Biamp Biamp Drywall ANSI NFPA 70 CSA C22 1 3...

Page 20: ...perar normalmente ou se tiver ca do AVISO Para reduzir o risco de inc ndio ou choque el trico n o exponha esses produtos chuva ou umidade Estes produtos n o devem ser expostos a goteiras ou respingos...

Page 21: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 100 POTS 26 AWG Biamp Biamp ANSI NFPA 70 1 CSA C22 1 2 128 12 010 3 12 100 4 2 1 5...

Page 22: ...ommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to rad...

Page 23: ...is presented to comply with Chinese law SJ T11363 2006 Hazardous Substances Table Biamp Systems Corporation Audio Output Device Vocia VO 4e Part Name Substances Pb Hg Cd Cr 6 PBB PBDE Equipment Chassi...

Page 24: ...ll become the property of Biamp Systems 4 This warranty will be VOID if the serial number has been removed or defaced or if the product has been altered subjected to damage abuse or rental usage repai...

Reviews: