INSTALLATION MANUAL
Logic
Deinition
Default
Cross out
setting
used
Optional extras
SAFE 1
Coniguration of
safety input SAFE 1.
72
0
0
Input conigured as Phot (photocell).
1
Input conigured as Phot test (tested photocell).
2
Input conigured as Phot op (photocell active during opening only).
3
Input conigured as Phot op test (tested photocell active during opening only).
SAFE 2
Coniguration of
safety input SAFE 2.
74
6
4
Input conigured as Phot cl (photocell active during closing only).
5
Input conigured as Phot cl test (tested photocell active during closing only).
6
Input conigured as Bar, safety edge.
7
Input conigured as Bar, tested safety edge.
8
Input conigured as Bar 8k2.
IC 1
Coniguration of
command input IC 1.
61
0
0
Input conigured as Start E.
1
Input conigured as Start I.
2
Input conigured as Open.
3
Input conigured as Close.
IC 2
Coniguration of
command input IC 2.
62
4
4
Input conigured as Ped.
5
Input conigured as Timer.
6
Input conigured as Timer Pedestrian.
AUX 3
Coniguration of
AUX 3 output.
26-37
0
0
Output conigured as 2nd Radio Channel.
1
Output conigured as SCA (gate open light).
2
Output conigured as Courtesy Light command.
3
Output conigured as Zone Light command.
4
Output conigured as Stair Light
5
Output conigured as Alarm
6
Output conigured as Flashing light
7
Output conigured as Latch
8
Output conigured as Magnetic lock
FIXED CODE
Fixed code
0
0
Receiver is conigured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is conigured for operation in ixed-code mode.
Fixed-Code Clones are accepted.
RADIO PROG
Transmitter
programming
1
0
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
1
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10s the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10s: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
SERIAL MODE
Serial mode
(Identiies how board
is conigured in a BFT
network connection).
0
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
ADDRESS
Address
0
[ ___ ]
Identiies board address from 0 to 127 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
36 -
THALIA
D811762 00100_05
Summary of Contents for THALIA
Page 79: ...THALIA 79 D811762 00100_05 ...
Page 80: ......