INSTALLATION MANUAL
Terminal
Deinition
Description
S
af
et
y de
vic
es
70
Common
STOP, SAFE 1 and SAFE 2 inputs common
71
STOP
The command stops movement. (N.C.)
If not used, leave jumper inserted.
72
SAFE 1
Conigurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input coniguration” table.
73
FAULT 1
Test input for safety devices connected to SAFE 1.
74
SAFE 2
Conigurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the “Safety input coniguration” table.
75
FAULT 2
Test input for safety devices connected to SAFE 2.
A
n
tenna
Y
ANTENNA
Antenna input.
Use an antenna tuned to 433MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can
interfere with radio reception. If the transmitter’s range is limited, move the antenna to a more suitable position.
#
SHIELD
AUX output coniguration
Aux logic= 0 - 2ND RADIO CHANNEL output.
Contact stays closed for 1s when 2nd radio channel is activated.
Aux logic= 1 - SCA GATE OPEN LIGHToutput.
Contact stays closed during opening and with leaf open, intermittent during closing, open with leaf closed.
Aux logic= 2 - COURTESY LIGHT command output.
Contact stays on for 90 seconds after the last operation.
Aux logic= 3 - ZONE LIGHT command output.
Contact stays closed for the full duration of operation.
Aux logic= 4 - STAIR LIGHT output.
Contact stays closed for 1 second at start of operation.
Aux logic= 5 - GATE OPEN ALARM output.
Contact stays closed if the leaf stays open for double the set TCA time.
Aux logic= 6 - FLASHING LIGHT output.
Contact stays closed while leaves are operating.
Aux logic= 7 - SOLENOID LATCH output.
Contact stays closed for 2 seconds each time gate is opened.
Aux logic= 8 - MAGNETIC LOCK output.
Contact stays closed while gate is closed.
Command input coniguration
IC logic= 0 - Input conigured as Start E. Operation according to
STEP-BY-STEP MOV
. logic. External start for traic light control.
IC logic= 1 - Input conigured as Start I. Operation according to
STEP-BY-STEP MOV
. logic. Internal start for traic light control.
IC logic= 2 - Input conigured as Open.
The command causes the leaves to open. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following
the TCA time, where activated.
IC logic= 3 - Input conigured as Closed.
The command causes the leaves to close.
IC logic= 4 - Input conigured as Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. Operation according to
STEP-BY-STEP
. logic
IC logic= 5 - Input conigured as Timer.
Operation same as open except closing is guaranteed even after a mains power outage.
IC logic= 6 - Input conigured as Timer Ped.
The command causes the leaf to open to the pedestrian (partial) opening position. If the input stays closed, the leaf stays open until the contact is opened. If the input stays closed and a Start E,
Start I or Open command is activated, a complete opening-closing cycle is performed before returning to the pedestrian opening position. Closing is guaranteed even after a mains power outage.
Safety input coniguration
SAFE logic= 0 - Input conigured as Phot (photocell) non tested (*). (ig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. When beam is broken, photocells are active during both opening and closing. When beam is broken
during closing, movement is reversed only once the photocell is cleared. If not used, leave jumper inserted.
SAFE logic= 1 - Input conigured as Phot test (tested photocell). (ig.F, ref.2).
Switches photocell testing on at start of operation. When beam is broken, photocells are active during both opening and closing. When beam is broken during closing, movement is
reversed only once the photocell is cleared.
SAFE logic= 2 - Input conigured as Phot op (photocell active during opening only) non tested (*). (ig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during closing. During opening, stops
motion for as long as the photocell beam stays broken. If not used, leave jumper inserted.
SAFE logic= 3 - Input conigured as Phot op test (tested photocell active during opening only (ig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during closing. During opening, stops motion for as long as the photocell beam stays broken.
SAFE logic= 4 - Input conigured as Phot cl (photocell active during closing only) non tested (*). (ig.F, ref.1).
Enables connection of devices not equipped with supplementary test contacts. In the event beam is broken, photocell operation is disabled during opening. During closing,
movement is reversed immediately. If not used, leave jumper inserted.
SAFE logic= 5 - Input conigured as Phot cl test (tested photocell active during closing only (ig.F, ref.2).
Switches photocell testing on at start of operation. In the event beam is broken, photocell operation is disabled during opening. During closing, movement is reversed immediately.
SAFE logic= 6 - Input conigured as Bar (safety edge) non tested (*). (ig.F, ref.3).
Enables connection of devices not equipped with supplementary test contacts. The command reverses movement for 2 sec.. If not used, leave jumper inserted.
SAFE logic= 7 - Input conigured as Bar (tested safety edge (ig.F, ref.4).
Switches safety edge testing on at start of operation. The command reverses movement for 2 sec.
SAFE logic= 8 - Input conigured as Bar 8k2 (ig.F, ref.5). Input for resistive edge 8K2.
The command reverses movement for 2 sec.
32 -
THALIA
D811762 00100_05