INSTALLATION MANUAL
2) GENERAL INFORMATION
The
THALIA
control panel comes with standard factory settings. Any change
must be made using the programmer with built-in display or universal handheld
programmer. The Control unit completely supports the EELINK protocol.
Its main features are:
- Control of 1 or 2 24V BT motors
Note: 2 motors of the same type must be used.
- Electronic torque control with obstacle detection
- Limit switch control inputs based on motor selected
- Separate inputs for safety devices
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer’s job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74. If the above-mentioned
terminals are being used, remove the relevant jumpers.
TESTING
The
THALIA
panel controls (checks) the start relays and safety devices (photocells)
before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
3) TECHNICAL SPECIFICATIONS
Power supply
220-230V 50/60 Hz*
Low voltage/mains insulation
> 2MOhm 500V
Operating temperature range
-20 / +55°C
Thermal overload protection
Software
Dielectric rigidity
mains/LV 3750V~ for 1 minute
Motor output current
max. 7.5A+7.5A
Motor relay switching current
10A
Maximum motor power
180W + 180W (24V
)
Accessories power supply
24V~ (demand max. 1A)
24V~safe
AUX 3
NO contact (24V~/max.1A)
Flashing light
24V~ max. 25W
Dimensions
see
Fig. B
Fuses
see
Fig. C
N° of combinations
4 billion
Max.n° of transmitters that can be memorized 63
(*other voltages to order)
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
4) TUBE ARRANGEMENT Fi g. A
5) TERMINAL BOARD WIRING Fig. C
WARNINGS -
When performing wiring and installation, refer to the standards in
force and, whatever the case, apply good practice principles.
Wires carrying diferent voltages must be kept physically separate from each other,
or they must be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devices
such as cable clamps.
All connecting cables must be kept far enough away from the dissipater.
WARNING! For connection to the mains power supply, use a multicore cable
with a cross-sectional area of at least 3x1.5mm
2
of the kind provided for by
the regulations in force.
To connect the motors, use a cable with a cross-sectional area of at least
1.5mm
2
of the kind provided for by the regulations in force. By way of example,
if the cable is run outside (unprotected), it must be at least type H07RN-F,
while if it is run inside (in a raceway), it must be at least type H05 VV-F.
Terminal
Deinition
Description
P
o
w
er supply
L
LINE
Single-phase power supply
220-230V 50/60 Hz*
N
NEUTRAL
JP5
TRANSF PRIM
Transformer primary winding connection, 220-230V.
JP7
JP21
TRANSF SEC
Board power supply:
24V~ Transformer secondary winding
24V= Bufer battery power supply
M
ot
or
10
MOT1 +
Connection motor 1. Time lag during closing.
Check connections shown in Fig.E
11
MOT1 -
14
MOT2 +
Connection motor 2. Time lag during opening.
Check connections shown in Fig.E
15
MOT2 -
Au
x
20
LIGHT 24v
Flashing light 24V output max. 25W.
21
26
AUX 3 - FREE
CONTACT
(N.O.)
(Max. 24V 1A)
AUX 3 conigurable output - Default setting 2ND RADIO CHANNEL Output.
2ND RADIO CHANNEL/ SCA GATE OPEN LIGHT/ COURTESY LIGHT command/ ZONE LIGHT command/ STAIR LIGHT/ GATE OPEN
ALARM/ FLASHING LIGHT/ SOLENOID LATCH/ MAGNETIC LOCK.
Refer to “AUX output coniguration” table.
27
Limit swit
ch f
or
ELI 250 B
T
41
+ REF SWE
Limit switch common
42
SWC 1
Motor 1 closing limit switch SWC1 (N.C.).
43
SWO 1
Motor 1 opening limit switch SWO1 (N.C.).
44
SWC 2
Motor 2 closing limit switch SWC2 (N.C.).
45
SWO 2
Motor 2 opening limit switch SWO2 (N.C.).
Limit swit
ch f
or
PHOBOS B
T -
IGEA B
T - SUB B
T
42
SW 1
Limit switch control motor 1.
For actuators with single-wire limit switch control.
43
SW 2
Limit switch control motor 2.
For actuators with single-wire limit switch control.
Limit swit
ch
for
LUX B
T
LUX G B
T
41
+ REF SWE
Limit switch common
42
SW 1
Limit switch control motor 1.
43
SW 2
Limit switch control motor 2.
A
cc
essories
p
o
w
er supply
50
24V-
Accessories power supply output.
51
24V+
52
24 Vsafe+
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
C
ommands
60
Common
IC 1 and IC 2 inputs common
61
IC 1
Conigurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input coniguration” table.
62
IC 2
Conigurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the “Command input coniguration” table.
ENGLISH
THALIA
31