ACCESS MENUS Fig. 1
stat
password
x 2
- +
- +
OK
vers
bft . . .
+
/
-
OK
0000
+
/
-
+
/
-
+
/
-
n. cycles
OK
OK
01.33
0---
10--
150-
1520
prg
00
-
+
err
autoset
l.sw adj
02.01
........
30.15
+
/
-
opm1
opm2
clm2
clm1
ersu
o
2
1
2
1
2
1
2
1
-
-
Exit Menù
Confirm/Switch on display
Scroll up
Scroll down
See PARAMETERS MENU
See LOGIC MENU
See RADIO MENU
add. start
hidden butt
hidden butt
release
release
desired button
desired button
Add. 2ch
erase 64
language
n. remotes
List of last 30 errors
Control unit
software version
No total
manoeuvres(in hundreds)
No radio control
devices memorised
ENGLISH
35.40
Instantaneous force motor 2
Instantaneous force motor 1
Diagnostics
code
DESCRIPTION
NOTES
STRE
START E external start input activated
STRI
START I internal start input activated
OPEN
OPEN input activated
CLS
CLOSE input activated
PED
PED pedestrian input activated
TIME
TIMER input activated
STOP
STOP input activated
PHOT
PHOT photocell input activated
PHOP
PHOT OP opening photocell input activated
PHCL
PHOT CL closing photocell input activated
BAR
BAR safety edge input activated
SWC1
SWC1 motor 1 closing limit switch input activated
SWO1
SWO1 motor 1 opening limit switch input activated
SWC2
SWC2 motor 2 closing limit switch input activated
SWO2
SWO2 motor 2 opening limit switch input activated
SET
The board is standing by to perform a complete opening-
closing cycle uninterrupted by intermediate stops in
order to acquire the torque required for movement.
WARNING! Obstacle detection not active
ER01
Photocell test failed
Check photocell connection and/or logic settings
ER02
Safety edge test failed
Check safety edge connection and/or logic settings
ER03
Opening photocell test failed
Check photocell connection and/or param-
eter/logic setting
ER04
Closing photocell test failed
Check photocell connection and/or param-
eter/logic setting
er06
8k2 safety edge test failed
Check safety edge connection and/or param-
eter/logic settings
ER1x
*
Board hardware test error
- C h e c k c o n n e c t i o n s t o m o t o r
- Hardware problems with board (contact
technical assistance)
ER2x
*
Encoder error
- M o t o r p o w e r o r e n c o d e r s i g -
n a l c a b l e s i n v e r t e d / d i s c o n n e c t e d .
- Actuator movement is too slow or stopped
with respect to programmed operation.
ER3x
*
Reverse due to obstacle - Amperostop
Check for obstacles in path
ER4x
*
Thermal cutout
Allow automated device to cool
ER5x
*
Communication error with remote devices
Check connection with serial-connected
accessory devices and/or expansion boards
ER7x
*
Internal system supervision control error.
Try switching the board of and back on again.
If the problem persists, contact the technical
assistance department.
Ersw
Error during limit switch adjustment
- Repeat the limit switch adjustment procedure.
- Try moving the maximum limits of both
the opening and closing limit switches.
- Caution: the last centimetre of the piston’s stroke,
during either opening or closing, cannot be used.
*
X
= 0, 1, .., 9, A, B, C, D, E, F
THALIA
29
D811762 00100_05
Summary of Contents for THALIA
Page 79: ...THALIA 79 D811762 00100_05 ...
Page 80: ......