INSTALLATION MANUAL
Logic
Definition
Default
Cross out
setting
used
Optional extras
AUX 1
Configuration of
AUX 1 output.
22-23
3
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
AUX 2
Configuration of
AUX 2 output.
24-25
1
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
AUX 3
Configuration of
AUX 3 output.
26-37
0
6
Output configured as Flashing light
7
Output configured as Latch
8
Output configured as Magnetic lock
LOCK
Type of lock.
28-29
0
0
Output configured as 12V
solenoid latch.
1
Output configured as 12V
magnetic lock.
2
Output configured as 24V
solenoid latch.
3
Output configured as 24V
magnetic lock.
FIXED CODE
Fixed code
0
0
Receiver is configured for operation in rolling-code mode.
Fixed-Code Clones are not accepted.
1
Receiver is configured for operation in fixed-code mode.
Fixed-Code Clones are accepted.
RADIO PROG
Transmitter pro-
gramming
1
0
Disables wireless memorizing of transmitters.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: Disables the automatic addition of new transmitters, clones and replays.
1
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10s the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10s: you can use this time to enter other new transmitters.
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
SERIAL MODE
Serial mode
(Identifies how board
is configured in a BFT
network connection).
0
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
ADDRESS
Address
0
[ ___ ]
Identifies board address from 0 to 127 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
EXPI1
Configuration of
EXPI1 input on
input-output expan-
sion board.
1-2
1
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as Phot test safety (tested photocell).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
12
Input configured as Phot op test safety (tested photocell active during opening only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device test
input, EXPFAULT1.
13
Input configured as Phot cl test safety (tested photocell active during closing only).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
14
Input configured as Bar safety (tested safety edge).
Input 3 (EXPI2) on input/output expansion board is switched automatically to
safety device test input, EXPFAULT1.
ENGLISH
THALIA P
37
D811780
00100_06