D812958 00100_03
RIGEL 6
- 45
ENGLISH
INSTALLATION MANUAL
TABLE “B” - LOGIC MENU - (
logic
)
Logic
Definition
Default
Cross out
setting
used
Optional extras
TCA
Automatic Closing
Time
0
0
Logic not enabled
1
Switches automatic closing on
FAST CLS.
Fast closing
0
0
Logic not enabled
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
STEP-BY-STEP
MOVEMNT
Step-by-step
movement
0
0
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
step-by-step mov.
2 STEP
3 STEP
4 STEP
CLOSED
OPENS
OPENS
OPENS
DURING
CLOSING
STOPS
OPEN
CLOSES
CLOSES
CLOSES
DURING
OPENING
STOP + TCA STOP + TCA
AFTER STOP
OPENS
OPENS
OPENS
1
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
2
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
PRE-ALARM
Pre-alarm
0
0
The flashing light comes on at the same time as the motor(s) start.
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
Parameter
min. max.
Default
Personal
Definition
Description
obst.sens.
0
99
0
Obstacle sensitivity
It allows activating obstacle detection.
The function is disabled when the parameter is set to 0, setting the value between 1 and
the maximum value, obstacle sensitivity can be increased (max value = max sensitivity).
ATTENTION: This obstacle detection function does not guarantee com-
pliance with the safety regulations in force (*). To comply with the current safety
regulations, install adequate anti-crushing safety devices (**).
ATTENTION: The system detects the obstacle only if the leaf is stopped; no
obstacles breaking the leaf without managing to stop it are detected.
Detection takes place only if the leaf meeting the obstacle is moving at normal
speed. The obstacle is not detected during slow-down.
The movement of the leaf is divided into these phases:
ACTIVE
1
2
3
4
1=
Pick-up
2=
Operating speed
3=
Slowdown
4=
Overtravel
The function is only active in phase
2
.
If the slowdown is not present (phase 3 not present), the last part of phase
2
(last 10% of
the operating phase, with a maximum limit of 9 seconds) is also deactivated
ACTIVE
1
2
4
10%
NOT ACTIVE
-10% of the course
(up to a maximum of 9 seconds)
1=
Pick-up
2=
Operating speed
4=
Overtravel
Do not use this function with hydraulic motors.
Leave default value set to 0.
(***)
Maintenance
0
250
0
Programming number of
operations for maintenance
threshold
[in hundreds]
Allows you to set a number of operations after which the need for maintenance will
be reported on the AUX output configured as Maintenance or Flashing Light and
Maintenance .
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
(**) The impact forces must be limited using active coasts comply with EN12978
(***)
CAUTION: After a parameter change will need to run an autoset function if the “obstacle sensitivity” is active.